Liao Chang-Sheng1,2, Lan Feng-Jun3,4, Liu Huan-Sheng3,4
1Department of Orthopaedics, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Wuhou District, Chengdu, 610041, Sichuan Province, P.R. China. 15603441409@163.com.
Background:
Unexpected microbial signals are frequently encountered in patients with orthopaedic implants who do not satisfy validated criteria for confirmed infection. The central interpretive problem is not limited to periprosthetic joint infection (PJI); it also arises in fracture-fixation and spinal instrumentation, and it involves conventional culture, sonication, histopathology, broad-range polymerase chain reaction (PCR), 16 S rRNA sequencing, and metagenomic next-generation sequencing (mNGS).
Methods:
We performed a structured narrative review of literature identified in PubMed, Embase, and Web of Science, updated through 27 June 2026. Eligible publications addressed microbial or biofilm-associated signals in orthopaedic implants without unequivocal infection at the time of sampling, or reported outcomes after unexpected positive cultures. Evidence was organized by implant type, indication for implant removal, detection method, host-response evidence, and longitudinal outcome. Particular attention was paid to the distinction between routinely removed fracture-fixation devices and failure-related arthroplasty or spinal revisions.
Results:
Routine removal of fracture-fixation devices provides the least confounded clinical window and demonstrates that microbial signals may be recovered from implants in the absence of recognized failure or overt infection. By contrast, arthroplasty and spinal cohorts labelled "presumed aseptic" are intrinsically confounded because pain, loosening, osteolysis, or pseudarthrosis may represent occult infection. Molecular positivity is further limited by low-biomass contamination and inability to distinguish viable organisms from relic DNA. Favorable outcomes after revision do not prove that infection was never present, because revision surgery itself may eradicate or substantially reduce an occult microbial burden.
Conclusions:
Microbial detection should be interpreted through three sequential domains: analytical credibility, biological activity or persistence, and clinical causality supported by host response or implant-related pathology. "Stable coexistence" is best treated as a longitudinal clinical phenotype or testable mechanistic hypothesis, not as an established diagnostic category. This framework complements, but does not replace, validated PJI, fracture-related infection (FRI), or other implant-specific definitions.
More Related Videos
10:04A Zebrafish Embryo Model for In Vivo Visualization and Intravital Analysis of Biomaterial-associated Staphylococcus aureus Infection
Published on: January 7, 2019
09:49Investigation of Microbial Cooperation via Imaging Mass Spectrometry Analysis of Bacterial Colonies Grown on Agar and in Tissue During Infection
Published on: November 18, 2022
Related Concept Videos
Bacterial Signaling
Infection
The chain begins with pathogens: bacteria, viruses, fungi, prions, or parasites such as protozoa helminths. These can be present on the skin as transient or resident flora, or they can be acquired from the environment. Identifying and treating the type of infection and...
Colonisation of Pathogens
Introduction to the Human Microbiota
Surface Membrane Barriers
The outer layer of the skin, the epidermis, is a robust barrier comprising layers of closely packed keratinized cells. This dense arrangement prevents microbes from penetrating the body. The periodic shedding of epidermal cells...
Microbial Biosensors