Related Experiment Videos

The Signal of Admixture Can Decay Rapidly When Using Clustering-Based Methods

Josia Shemuel1, Sonal Singhal2, Craig Moritz1

  • 1Division of Ecology & Evolution, The Australian National University, Canberra, Australian Capital Territory, Australia.

Related Concept Videos

Cluster Sampling Method01:20

Cluster Sampling Method

Appropriate sampling methods ensure that samples are drawn without bias and accurately represent the population. Because measuring the entire population in a study is not practical, researchers use samples to represent the population of interest.
To choose a cluster sample, divide the population into clusters (groups) and then randomly select some of the clusters. All the members from these clusters are in the cluster sample. For example, if you randomly sample four departments from your...
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹H NMR Signal Integration: Overview00:58

¹H NMR Signal Integration: Overview

The intensity of a signal, which can be represented by the area under the peak, depends on the number of protons contributing to that signal. The area under each peak is shown as a vertical line called an integral, with the integral value listed under it, as seen in the proton NMR spectrum of benzyl acetate. Each integral value is divided by the smallest integral value to obtain the ratio of the number of protons producing each signal. The ratio reveals the relative number of protons and not...
Aliasing01:18

Aliasing

Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...