Related Experiment Video
Updated: Oct 14, 2026

Phase-Resolved Functional Lung MRI for Pulmonary Ventilation and Perfusion (V/Q) Assessment
Published on: August 9, 2024
Evaluating Perfusion Quantification for Phase-Resolved Functional Lung MRI Using Gaussian Filtering
Kirsten J Schmidt1,2, Andreas Voskrebenzev1,2,3, Julian M W Glandorf1,2
1Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.
Abstract:
Phase-resolved functional lung (PREFUL) MRI enables contrast-free lung perfusion quantification (QQuant). Current quantification uses a single median value per slice of maximal blood exchange fraction (ΔS), which limits regional assessment, whereas regional ΔS causes artifacts. This retrospective study aims to optimize QQuant by applying Gaussian filtering to ΔS to improve intrascan/interscan repeatability in healthy volunteers, while evaluating whether the optimized QQuant retains agreement with dynamic contrast-enhanced (DCE) MRI in chronic obstructive pulmonary disease (COPD) and chronic thromboembolic pulmonary hypertension (CTEPH) patients and exhibits a physiologically plausible gravity-dependent perfusion gradient. Analysis was performed on 29 healthy subjects (11 female, age: 19-33 years), 20 COPD patients (three female, age: 46-76 years) and 15 CTEPH patients (six female, age: 44-82 years), scanned at 1.5 T. Healthy subjects underwent four PREFUL scans in two sessions. Patients just underwent one PREFUL and DCE scan. QQuant maps were calculated while applying different Gaussian filter options to ΔS. In patients, PREFUL-derived QQuant maps were coregistered to DCE-derived pulmonary blood flow (PBF) maps for global and voxel-wise correlations. In healthy subjects, the gravity-dependent perfusion gradient was quantified by linear regression of slice-wise QQuant across five coronal slices. Gaussian filtering ΔS with σ = 1.5 improved intrascan and interscan repeatability in healthy subjects (mean bias: ≤ 2.94 mL/100 mL; Cohen's d: 0.2) compared with the current slice median setting (mean bias: ≥ 3.75 mL/100 mL; Cohen's d: 0.68). Correlations with PBF remained stable after filtering (σ = 1.5) in COPD (filtered vs. default ΔS: global r = 0.57 vs. r = 0.59, voxel-wise r = 0.32 vs. r = 0.32) and CTEPH (global r = 0.32 vs. r = 0.28, voxel-wise r = 0.40 vs. r = 0.41), all significant except global CTEPH. The filtered QQuant maps showed a significant gravity-dependent perfusion gradient (ΔS filtered σ = 1.5) of 1.47 mL/min/100 mL/cm. Gaussian filtering ΔS with σ = 1.5 improved QQuant repeatability while preserving DCE-MRI agreement and is therefore recommended. The observed gravity-dependent perfusion gradient confirms physiological plausibility, supporting potential in clinical use.