Related Experiment Video
Updated: Oct 14, 2026

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Evaluation of cardiovascular risk using smartwatch-measured pulse wave velocity in China: a nationwide
Luyan Wang1, Ningling Sun1, Hongyi Wang1
1Department of Hypertension, Peking University People's Hospital, Beijing, China.
Background:
Cardiovascular and cerebrovascular diseases, driven by arteriosclerosis, are China's leading causes of death. Smartwatch-measured pulse wave velocity (SW-PWV) is an algorithm-derived estimate of carotid-femoral pulse wave velocity (cfPWV) generated using a built-in machine-learning algorithm. A previous validation study showed good agreement between smartwatch-estimated cfPWV and Complior Analyse measurements, with a concordance correlation coefficient of 0.9045 and a mean absolute error of 0.66 m/s.
Objective:
This study aimed to describe the distribution of smartwatch-measured pulse wave velocity (SW-PWV) according to age, sex, and body mass index (BMI), and to investigate its cross-sectional associations with cardiovascular risk factors and established cardiovascular disease (CVD).
Methods:
This cross-sectional study analyzed 165,549 users who completed at least one valid SW-PWV measurement using compatible Huawei smartwatches between December 2020 and August 2022. Analyses of cardiovascular risk factors and CVD were restricted to 35,402 users who completed the "Vascular Health" app questionnaire, in which physician-diagnosed conditions were self-reported according to predefined criteria. A threshold of 10 m/s, adapted from guideline recommendations for cfPWV, was explored for SW-PWV. Spearman's correlation, Kruskal-Wallis test, multiple regression, and Mann-Whitney U-test were used for analysis. Data were reported as median (interquartile range) or mean ± standard deviation.
Results:
SW-PWV correlated positively with age, male sex, and BMI. After age- and BMI-stratification, SW-PWV increased progressively across all cohorts. Average SW-PWV was significantly higher in males than in females. SW-PWV was significantly elevated in participants with hypertension, diabetes, dyslipidemia, coronary heart disease, stroke, and carotid plaque, with hypertension and carotid plaque exhibiting the strongest correlations. SW-PWV demonstrated moderate discrimination for prevalent CVD (area under the curve = 0.71). When applying the guideline-recommended cfPWV threshold of 10 m/s to SW-PWV, sensitivity was 13.6% and specificity was 96.7%.
Conclusion:
In this cross-sectional study, SW-PWV was associated with age, sex, and BMI, with SW-PWV ≥10 m/s linked to a higher prevalence of cardiovascular risk factors and CVD. These findings suggest that the guideline-derived 10 m/s threshold of cfPWV might serve as a preliminary or exploratory threshold reference for SW-PWV, though direct validation against conventional cfPWV and prospective longitudinal studies are required before clinical implementation.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse Assessment Sites
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring pulse

