Introduction:
Cardiac arrhythmias often progress without clear symptoms and may remain undetected until severe complications occur. Continuous monitoring through consumer smartwatches offers a scalable and non-invasive opportunity for real-time rhythm screening in free-living conditions. However, wrist-based photoplethysmography (PPG) signals are highly susceptible to motion artifacts and inter-subject variability, limiting traditional signal-processing techniques. In this work, we compare classical machine learning and deep learning approaches for multi-class arrhythmia classification from real-life smartwatch PPG and accelerometer recordings collected in the Pulsewatch clinical trial. Three rhythm categories are considered: normal sinus rhythm (NSR), atrial fibrillation (AF), and premature atrial or ventricular contractions (PAC/PVC).
Methods:
The evaluated approaches include a Random Forest classifier based on engineered temporal and morphological features, together with two end-to-end architectures, CNN-GRU and CNN-BiLSTM, designed to learn temporal patterns directly from raw two-channel smartwatch waveforms while addressing motion artifacts, sensor noise, and cross-subject generalization.
Results:
Under two-fold subject-independent cross-validation, the Random Forest achieved the highest average accuracy among the proposed methods (91.22%), together with the best macro precision (85.89%), macro F1 score (84.17%), and macro ROC-AUC (97.03%). The CNN-BiLSTM achieved the highest macro recall (87.37%), indicating stronger sensitivity to arrhythmic classes, while the CNN-GRU remained competitive with a macro recall of 86.85% and a macro F1 score of 83.13%.
Discussion:
Compared with the Pulsewatch baselines reported by Han et al., the proposed methods improved the available macro-level metrics, with the Random Forest obtaining the strongest macro precision and macro F1 score and the CNN-BiLSTM the strongest macro recall, indicating improved class-balanced recognition of clinically relevant arrhythmic events. These results show that feature-based models remain highly competitive for smartwatch-based arrhythmia detection, achieving the strongest overall and macro F1 performance among the proposed methods, while hybrid convolutional-recurrent architectures provide increased sensitivity to minority rhythm classes. Deployment-oriented profiling under an identical single-core benchmark showed a mean end-to-end inference time of 33.08 ms for the Random Forest pipeline and 51.87 ms for the CNN-BiLSTM model on a 30-s segment, supporting near-real-time rhythm screening.
Conclusion:
Overall, this work highlights the trade-offs between the analyzed approaches in terms of accuracy, class-balanced performance, computational complexity, and deployment feasibility for wearable cardiac monitoring systems.
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...