Per-Class Conformal Risk Control for Multi-Label ECG Classification: Achieving Clinically-Justified False Negative
Oussama El Allam1, Mohamed Hamlich1
1Université Hassan II Casablanca ENSAM, 150 Bd du Nil, Casablanca, Grand Casablanca, 20670, Morocco.
Objective:
Automated electrocardiogram (ECG) classifiers require uncertainty procedures that address class-specific clinical risk in intrinsically multi-label data. Approach: We propose per-class risk-controlling prediction sets for multi-label ECG classification. For each diagnostic class, binary false-negative-rate (FNR) loss is calibrated with a one-sided exact-binomial upper confidence bound. The nine disease-specific targets are controlled simultaneously at 95% family-wise confidence using Bonferroni allocation. The final operating threshold is the more inclusive of the exact-binomial threshold and a conservative reference threshold derived from a concentration bound; this safeguard uses calibration data only and cannot weaken the exact guarantee. Main results: We evaluated the method on PTB-XL (21,388 retained recordings) and Chapman-Shaoxing (10,199 retained recordings), using a patient-disjoint PTB-XL split and fitting-partition-only normalisation. The proposed method met all 9/9 prespecified disease-specific FNR targets on held-out test sets and produced non-vacuous simultaneous exact-binomial guarantees for all nine targets; uniform standard conformal prediction met 5/9. Test FNR was 0.0% for myocardial infarction (exact 95% upper bound 0.35%, at 80.3% FPR), 1.0% for ST/T changes, and 0.3% for atrial fibrillation; the high-sensitivity operating point is purchased with substantially reduced specificity. Under PTB-XL-to-Chapman shift, macro class coverage fell from 94.3% to 45.5%, demonstrating that the guarantees do not transport without local recalibration. Significance: Exact-binomial per-class risk control provides a transparent high-sensitivity operating point for ECG triage while making its specificity, prediction-set-size, calibration-support, and exchangeability limitations explicit. .
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...