A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
High-flow oxygen for apnea testing in brain death determination
Vincent Legros1, Paul Chabot2, Elodie Gelisse2
1Service d'anesthésie-réanimation et médecine péri-opératoire, Hôpital Maison Blanche, CHU de Reims, F-51000, Reims, France; Université de Reims Champagne-Ardenne, VieFra, Reims, F-51100, France.
Background:
Apnea testing is mandatory for brain death determination but may induce hypoxemia despite standard preoxygenation procedures. High-flow oxygen (HFO) systems may improve apneic oxygenation during the procedure, although clinical data remain limited.
Methods:
We conducted a retrospective single-center cohort study including consecutive adult patients undergoing apnea testing for brain death determination between January 2023 and May 2026. Standard oxygen insufflation (6-15 L/min) was compared with HFO delivered through the Opt970® interface (Fisher & Paykel) at 50 L/min and FiO2 1.0. The primary outcome was longitudinal pulse oximetry saturation (SpO2) evolution during apnea testing. Secondary outcomes included desaturation events and arterial blood gas parameters. Repeated SpO2 measurements were analyzed using a linear mixed-effects model.
Results:
A total of 144 apnea tests were analyzed, including 78 using standard oxygen insufflation and 66 using HFO. Baseline characteristics and ventilatory parameters were comparable between groups. Lowest SpO2 during apnea testing was significantly higher with HFO (100 [98-100] vs. 99 [95-99]; p = 0.003), while desaturation below 94% occurred less frequently (9.1% vs. 21.8%; p = 0.04). Post-test PaCO2 was slightly higher in the HFO group (73 [67-81] vs. 70 [62-77] mmHg; p = 0.04). Longitudinal mixed-effects analysis demonstrated a significant decrease in SpO2 over time in both groups (p < 0.0001). However, HFO was associated with overall higher SpO2 values throughout the procedure (β=+1.38; standard error 0.69; p = 0.047), without significant group-by-time interaction (p = 0.578).
Conclusion:
HFO delivered through the Opt970® device was associated with modestly higher oxygen saturation during apnea testing compared with standard oxygen insufflation. Further prospective studies are required to confirm these findings.
More Related Videos
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Acute Respiratory Failure-IV
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.