Characterizing Bacterial Volatiles using Secondary Electrospray Ionization Mass Spectrometry (SESI-MS)
Published on: June 8, 2011
Long-term performance monitoring of a secondary electrospray ionisation high-resolution mass spectrometry platform
Albin Vadakkechira1, Renato Zenobi1, Daniel Pohl2
1Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 3, Zurich, 8093, Switzerland. stamatios.giannoukos@org.chem.ethz.ch.
Abstract:
Secondary electrospray ionisation high-resolution mass spectrometry (SESI-HRMS) is a powerful, non-invasive tool for real-time breath analysis. However, instrumental drift, capillary degradation and other technical variations compromise clinical applications, especially for long-term studies, which require robust quality control (QC) methodologies. In this work, we present the use of an evaporation chamber-based reference gas system to monitor SESI-MS system performance over almost two years. Targeted QC measurements with deuterated butyric acid were recorded three times on each measurement day. Analytical stability was systematically quantified across both positive and negative ion modes. In a standalone continuous characterization, the reference gas generator delivered a stable signal over several hours. A Linear Mixed-Effects Model (LMM) was constructed to evaluate the influence of time-of-day on instrument performance. This revealed significant effects: positive mode signal intensity progressively increased throughout the day, whereas for negative mode, an initial drop in signal intensity and subsequent stabilisation was observed. Furthermore, the longitudinal QC framework successfully tracked capillary performance over time, providing objective performance metrics to retrospectively evaluate the impact of targeted hardware maintenance on system performance. The implementation of a structured QC protocol provides a valid methodology for long-term SESI-HRMS performance monitoring, ensuring data integrity and supporting the translation of SESI-HRMS into large-scale clinical applications.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Instrumentation
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...