Apparent versus Cross-Validated Selectivity in Seawater Electrolysis: Linking Product Analysis to

Gisang Park1, Joon Yong Park1, Amit Kumar Bera1

  • 1Department of Chemistry and Institute for Future Earth, Pusan National University, Busan46241, Republic of Korea.

Related Concept Videos

Processes at Electrodes01:30

Processes at Electrodes

The electrode interacts with ions in the electrolyte solution at its interface. The rate of oxidation and reduction depends on the speed at which electrons can transfer through this interface. As ions attach to or leave the electrode surface, the electrode acquires a charge, and an electrical potential forms across the interface, making the process more difficult to reach equilibrium. The charge on the electrode affects the local ion concentrations in the solution, though thermal motion...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current passing...
Electrogravimetric Analysis: Overview01:30

Electrogravimetric Analysis: Overview

Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
The Electrical Double Layer01:30

The Electrical Double Layer

In the region where two bulk phases meet, an intricate electric charge distribution arises due to charge transfer, ion adsorption, molecular orientation, and charge distortion. This complex distribution is commonly referred to as the electrical double layer.When a solid electrode interfaces with ions in an electrolyte solution, the speed of electron transfer dictates the rates of oxidation and reduction. The electrode acquires a charge through the escape of atoms into the solution as cations or...