Image Acquisition Method for the Sonographic Assessment of the Inferior Vena Cava
Published on: January 13, 2023
Intra- and Inter-Operator Reliability of Internal Jugular Vein Ultrasound Image Acquisition by Ultrasound-Naive
Yukie Tamura1, Kazumi Ishii1, Miharu Matsumoto2
1Faculty of Nursing, Ishikawa Prefectural Nursing University, 1-1, Gakuendai, Kahoku 929-1210, Ishikawa, Japan.
Abstract:
Background: Venous congestion assessment is essential in heart failure management. Inferior vena cava (IVC) ultrasonography has been widely used to determine fluid status but may not always provide satisfactory images. Hence, internal jugular vein (IJV) ultrasonography has been proposed as an alternative; however, the reliability of IJV ultrasound image acquisition by nurses without previous clinical ultrasound experience remains unclear. This study evaluated the intra- and inter-operator reliability of IJV ultrasound image acquisition by nurses without previous clinical ultrasound experience. Methods: Two nurses without prior clinical ultrasound experience acquired right IJV ultrasound images after preparatory training. Short-axis cine loops were obtained during quiet breathing and the Valsalva maneuver in healthy adults. A single investigator measured the major and minor diameters from selected still frames. Intra- and inter-operator reliability were then assessed using intraclass correlation coefficients (ICCs), after which agreement was evaluated by Bland-Altman analysis. Results: Both nurses successfully acquired IJV images suitable for subsequent quantitative analysis from all participants. Intra-operator reliability ranged from good to excellent, with ICC (1, 1) values of 0.765-0.967. Meanwhile, inter-operator reliability ranged from moderate to excellent, with ICC (2, 1) values of 0.629-0.916. Bland-Altman analysis revealed fixed bias in three parameters but no proportional bias. Absolute bias was <1 mm for all measurements. Conclusions: Following preparatory training, nurses without prior clinical ultrasound experience were able to acquire IJV ultrasound images with moderate-to-excellent inter-operator and good-to-excellent intra-operator relative reliability.
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies II: Ultrasonography
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: