Related Experiment Video
Updated: Oct 17, 2026

Scanning Skeletal Remains for Bone Mineral Density in Forensic Contexts
Published on: January 29, 2018
Benchmarking Gemini 1.5 Pro in Pediatric Emergency Radiology: Sensitivity Gap and Physiological Bias in the Immature
Cristiano Benelli1, Luca Labianca1, Vito Caiolo1
1Orthopedic Unit, Sant'Andrea Hospital, University of Rome La Sapienza, Via di Grottarossa 1035, 00189 Rome, Italy.
Abstract:
Background/Objectives: To assess the diagnostic performance of Gemini 1.5 Pro, a general-purpose Large Multimodal Model (LMM), as a zero-shot, smartphone-based decision support tool to distinguish pediatric fractures from healthy controls. Methods: A retrospective diagnostic accuracy study was conducted on 182 pediatric radiographs (112 confirmed fractures, 70 healthy controls) using the Gemini 1.5 Pro mobile interface with a 4-question prompt protocol (Detection, Characterization, Skeletal Maturity, Management). Diagnostic metrics were calculated with 95% Confidence Intervals (95% CI). Ground truth was established by a senior musculoskeletal radiologist. Results: The model showed an overall sensitivity of 90.2% (95% CI: 83.1-95.0%) and specificity of 87.1% (95% CI: 77.0-93.9%). A significant sensitivity gap occurred between displaced (100.0%; 95% CI: 91.4-100.0%) and non-displaced fractures (84.5%; 95% CI: 74.0-92.0%; p = 0.007). Qualitative taxonomy revealed a primary physiological bias leading to a 12.8% false-positive rate due to growth plate misinterpretation, alongside minor characterization and localization errors (3.6% of correctly identified fractures). When fractures were correctly identified, proposed management strategies aligned with international standards in 95.0% of cases. Inter-observer reliability was excellent (weighted k = 0.96). Conclusions: Gemini 1.5 Pro displays robust clinical reasoning for obvious trauma. However, its zero-shot performance is limited by subtle morphological disruptions and developmental anatomical nuances such as open growth plates. It shows promise as a mobile clinical decision support system for non-specialists, but expert human supervision remains necessary to ensure safety in the complex radiographic landscape of the immature skeleton.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
X-ray Imaging