Related Experiment Video
Updated: Oct 17, 2026

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
LGH-Transformer: A Hybrid CNN-Transformer Model for Multi-Class Bladder Tissue Classification from Cystoscopic Images
Hasan Anıl Kurt1, Sabire Kılıçarslan2, Meliha Merve Çiçekliyurt3
1Department of Urology, Faculty of Medicine, Çanakkale Onsekiz Mart University, 17100 Çanakkale, Turkey.
Abstract:
Automated analysis of cystoscopic images may support consistent characterization of bladder tissue patterns, but reported performance is highly sensitive to patient composition, data partitioning, and evaluation methodology. Objective: This study provides an exploratory comparison of convolutional neural networks, Transformer-based models, and a proposed Local-Global Hybrid Transformer (LGH-Transformer) for four-class bladder tissue image classification. The dataset comprised 1754 frames and used the publicly released 1257/308/189 training-validation-held-out test split. The annotation-defined held-out test composition was HGC = 74, LGC = 53, NST = 37, and NTL = 25 (n = 189). Images were resized to 224 × 224 pixels, normalized, and augmented only in the training subset. Adam and RMSprop were evaluated. Accuracy and macro-averaged precision, recall, and F1-score were calculated from the integer-count evaluation matrices. The highest held-out accuracy, 187/189 (0.9894), was reached by seven model-optimizer configurations: DenseNet201-RMSprop, XCiT Medium 24 P16-Adam, ConvNeXt Base-Adam, CoAtNet-Adam, ConvNeXt Base-RMSprop, CoAtNet-RMSprop, and the proposed LGH-Transformer-RMSprop; MobileNet-Adam and Xcep-tion-RMSprop each yielded 185/189 (0.9788), and LGH-Transformer-Adam yielded 186/189 (0.9841). On a 189-frame test set, differences in one to two frames do not establish statistical superiority, so these configurations are reported as a top-accuracy tier rather than as a ranked superiority claim. Within this tier, the LGH-Transformer had the smallest computational footprint (≈18.2 M parameters and ≈4.1 GFLOPs, versus 20.0-88.6 M parameters and 4.3-16.2 GFLOPs for the other top-tier models). Component-wise ablation experiments showed accuracy decreases of 0.0106, 0.0053, and 0.0053 after removing the CNN tokenizer, local attention, and global attention, respectively. The LGH-Transformer reaches the top accuracy tier of this 18-architecture benchmark at the lowest parameter and FLOP budget within that tier, supporting an internally consistent, efficiency-oriented comparison within the available cohort. The absence of task-aligned external validation and the small number of held-out patients require the findings to be interpreted as exploratory internal validation rather than evidence of clinical generalizability.