Related Experiment Video
Updated: Oct 17, 2026

An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
Enhanced Cadmium Detection in Real Water Sources Using a Custom Nanocomposite-Modified Carbon Electrode and Optimized
Dipen Basnet1, Rohit Boddu1, Xiyuan Liu2
1Institute for Micromanufacturing (IfM), Louisiana Tech University, Ruston, LA 71272, USA.
Abstract:
Monitoring toxic heavy metals in complex, real water sources is essential for safe water supplies. Current sensors lack the sensitivity, selectivity, and limits of detection (LOD) needed to detect heavy metals such as cadmium (Cd2+) in real water samples with minimal preparation. Here, we demonstrate a novel ternary nanocomposite-coated carbon electrochemical sensor that detects Cd2+ with the highest sensitivity (14.71 ± 0.3, 6.94 ± 0.8 μA·ppb-1·cm-2) and the lowest LODs (0.06 ± 0.02, 0.61 ± 0.10 ppb) in spiked deionized and lake waters, respectively. Sensor fabrication optimization included electrochemical polishing of carbon screen-printed electrodes, surface modification with a 1 mg/mL bismuth-reduced graphene-molybdenum disulfide nanocomposite ink, and rapid heating and cooling at 75 °C for 3 min. These steps, along with square wave anodic stripping voltammetry (SWASV) deposition potential identification, produced distinct detection peaks and high reproducibility (8% RSD). We further investigated the SWASV parameters, specifically frequency (5 to 50 Hz), amplitude (1 to 100 mV), and step potential (5 to 70 mV), using a fast causal inference algorithm, which resulted in a 233-fold increase in Cd2+ sensitivity. We found that the LOD and the full width at half maximum of the Cd2+ peak are dependent on frequency, while sensitivity and peak resolution depend on amplitude and step potential. Under optimal detection conditions of 35 Hz, 60 mV amplitude, and a 10 mV step potential, the sensor showed adequate sensitivity and LODs, even in the presence of 10-fold concentrations of Zn2+, As3+, and Cu2+ as interferents, confirming its suitability for real-world water-quality field testing.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
17:16Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
Published on: June 3, 2018
Related Concept Videos
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...