Topology-Guided Sparse Voltage Measurement Placement for Transient-Voltage Fault-Bus Localization: A Physically
Jisheng Xing1, Zhankun Wang1, Yu Xu1
1College of Electrical and Information Engineering, Beihua University, Jilin 132021, China.
Abstract:
Sparse voltage measurements make fault-bus localization depend on measurement placement and the physical distinguishability of location labels. We evaluate a deterministic, label-independent topology-guided placement protocol with physically governed localization classes and leakage-resistant condition-level validation on IEEE39 and IEEE123. In the original base protocols, topology-guided CNN1D Top-1 accuracy exceeded the prespecified primary-random layouts by 4.55 and 1.67 percentage points, respectively, although both paired bus-by-condition intervals included zero. In the reviewer-driven 1701-event IEEE39 physical-condition extension, Top-1 was 0.3683 for topology-guided placement and 0.3564 for primary random; the paired difference was +0.0119 with a 95% interval of -0.0493 to 0.0898, which also included zero. Separately, complete enumeration of all 84 feasible IEEE39 k = 3 layouts ranked the topology-guided layout first in Top-1 accuracy, Macro-F1, and mean-hop error under the frozen CNN1D protocol. Load-shift tests produced near-chance Top-1 values, and resistance-shift performance was lower at 20 Ω than at 0.1 Ω. Fixed-capacity, classifier, noise, timing, confusion, and topology-error analyses further bounded the result. The evidence supports reproducible pre-training measurement planning within the tested simulations without establishing statistically certain or universal superiority.
Related Concept Videos
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Power System Three-Phase Short Circuits
Fault Types
For line-to-line faults occurring between phases B and C, the...
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists of...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by: