Groove-Based Calibration of Multicore Fiber Bragg Grating Shape Sensors with Rotation-Angle Correction
Yi Jiang1, Martin Angelmahr2, Ahmad Abdalwareth1,2
1Institute for Energy Research and Physical Technologies (IEPT), Clausthal University of Technology, Am Stollen 19B, 38640 Goslar, Germany.
Abstract:
Fiber-optic shape sensors require accurate calibration of the spatial orientation and effective core distances of their sensing planes. We present a rotation-angle correction procedure for sinusoidal calibration of multicore fiber Bragg grating (MCF-FBG) shape sensors. The method is demonstrated using a constant-radius groove template and a single rotation stage. Within the groove fixture, groove-fiber friction, finite torsional stiffness, and non-ideal boundary conditions may contribute to deviations between the local sensor-plane rotation and the motor-imposed angle, resulting in distorted sinusoidal wavelength responses and biased curvature estimation. The proposed method addresses deviations from the assumed sinusoidal response by jointly correcting the effective rotation angle assigned to the four FBG responses in each sensor plane while leaving the measured wavelength shifts unchanged. The method was demonstrated using a 20 cm four-core single-mode fiber containing 200 femtosecond-laser-inscribed FBGs arranged in 50 sensor planes at 4 mm spacing. Quantitative validation with planar constant-curvature templates showed tip-position errors of approximately 2-5 mm, compared with approximately 6-13 mm for conventional sine calibration. An additional endpoint-position test of the 50-plane sensor yielded a mean error of 11.28 mm and an RMSE of 13.73 mm, compared with 19.03 mm and 21.55 mm, respectively, for conventional sine calibration. Additional non-planar bending tests qualitatively illustrated the sensor's three-dimensional reconstruction capability. The results show that rotation-angle correction can improve calibration accuracy while retaining a single-rotation-stage groove fixture.
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Gyroscope: Precession
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Unsymmetric Bending - Angle of Neutral Axis
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal centroidal axes. The...
Gyroscope
Angle of Twist: Problem Solving