Automatic analyses of quantitative dried material spots by on-line coupling of sequential injection to
Miloš Dvořák1, Carlos Pagan-Galbarro2, Manuel Miró2
1Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, Brno, CZ-60200, Czech Republic.
Background:
The development and integration of platforms for reliable handling of dried material spots (DMSs) as a front-end to advanced analytical instrumentation continues to pose methodological challenges. Although robotic platforms have been developed for autonomous manipulation of dried blood spot (DBS) cards, these systems exhibit limited flexibility regarding ancillary unit operations and remain incompatible with quantitative DMS (qDMS) devices.
Results:
Leveraging off-the-shelf fluidic components using advanced liquid handling, this proof-of-concept work exploits the versatility of sequential injection-high-performance liquid chromatography (SI-HPLC) coupling for automatic processing and analysis of DMSs. The flow setup features a multi-position rotary valve as the core of the SI manifold connected to two 3D-printed 60-position racks. This hyphenation enables flexible in-vial processing of various DBS, qDBS, qDMS, and volumetric absorptive microsampling (VAMS) samples by controlled dispensing of microliter volumes of methanol for the spot rehydration, protein precipitation, and analyte elution, followed by mixing and homogenization of the eluate with water for the HPLC compatibility. Demonstrated on model non-steroidal anti-inflammatory drugs, the fully synchronized SI-HPLC setup enabled entirely unsupervised analysis of up to 120 DMS samples with triplicate HPLC injections per eluate (8.2 min each). Using a matrix-matched calibration based on spiking 10 μL of analyte-free blood, multiple qDBSs were eluted with 135 μL of methanol, followed by the eluate composition adjustment with 135 μL of water for HPLC compatibility prior to reversed-phase HPLC analysis. Under these conditions, calibrations were linear over 15 - 60, 0.8 - 12, 0.8 - 6, and 6.2 - 100 μg mL-1 ranges, and LODs were 5.7, 0.3, 0.3, and 1.4 μg mL-1 for ibuprofen, ketoprofen, diclofenac, and naproxen, respectively. The method precision was 2.3 - 12.7% RSD for intra-day and 9.3 - 13.2% RSD for inter-day experiments. The reliability of the proposed automatic SI-HPLC setup was demonstrated for qDBSs with therapeutic naproxen levels, with no statistically significant concentration differences at the 0.05 level when compared to manual qDBS processing with off-line analysis by capillary electrophoresis.
Significance:
For the first time, the proposed analytical concept enables automatic handling and analysis of various DMS and qDMS samples, while using standard off-the-shelf SI and HPLC components and freely available control software.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: