Related Experiment Video
Updated: Oct 19, 2026

Measuring Maxillary Posterior Tooth Movement: A Model Assessment using Palatal and Dental Superimposition
Published on: February 23, 2024
Accuracy of soft tissue profile predictions using WebCeph and Dolphin software in non-growing skeletal Class II cases
Sara Abou Chedid1, Marianne Moussallem2, Roula Akl1
1Department of Orthodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon.
Introduction:
Aesthetic outcomes are a primary concern for adult orthodontic patients. Clinicians often rely on soft tissue simulation software, such as Dolphin Imaging (D-Tech) and WebCeph (D-Tech), to manage patient expectations. This study aimed to compare the accuracy of these two tools in predicting soft tissue profile changes in non-growing skeletal Class II patients treated with maxillary first premolar extractions.
Methods:
A retrospective comparative study was conducted on patients treated by the same practitioner with bilateral maxillary first premolar extractions and maximum anchorage. From a private-practice database of 2535 patients treated between January 2015 and January 2025, 34 met the inclusion criteria after eligibility screening. Pre- and post-treatment lateral cephalometric radiographs and profile photographs were used to generate simulations. Predicted cephalometric measurements from D-Tech and W-Tech were compared with each other and with the actual post-treatment results. Statistical analyses included paired t-tests, one-sample t-tests, Bland-Altman plots, and linear regression.
Results:
Thirty-four patients (10 males, 24 females; 35.7±3.5 years) were analysed. Both tools showed a significant discrepancy in the nasolabial angle versus actual results (P<0.001). D-Tech differed significantly in the subnasale to Holdaway-line distance (mean difference 0.81mm [95% CI 0.03 to 1.60]; P=0.042), while W-Tech differed in upper and lower lip position relative to the True Vertical Line (LL-TVL P=0.004; UL-TVL P=0.006). For the remaining parameters, both tools showed good agreement; D-Tech showed a proportional bias for lip-TVL position (greater underestimation at larger values), whereas W-Tech overestimated lower lip thickness.
Conclusion:
Both Dolphin Imaging and WebCeph provide clinically applicable predictions for most soft tissue parameters. Several statistically significant lip-position discrepancies were within the range generally considered clinically imperceptible (=1.5-2.0mm), whereas the nasolabial angle showed a discrepancy that is both statistically and clinically relevant. Predictions should therefore be interpreted with caution, particularly for parameters prone to systematic bias.