Related Experiment Video
Updated: Oct 24, 2026

Real-Time Electrocardiogram Monitoring During Treadmill Training in Mice
Published on: May 5, 2022
Estimation of respiration rate from nonclinical telemetry ECG data
Kavyakantha Remakanthakurup Sindhu1, Julia C Hotek2, Jude W Ferraro2
1Data, AI, & Genome Sciences, Merck & Co., Inc, Rahway, NJ, USA.
Abstract:
Assays to assess respiratory function are included in the ICH S7A guidance for Safety Pharmacology, which identifies the core in vivo studies required to evaluate safety prior to First in Human (FIH) dosing. This requirement is most commonly met using dedicated stand-alone rodent respiratory studies that require additional studies and increased resources. More importantly, the demonstrated transitional value of dedicated respiratory endpoints to predict risk and improve FIH safety is lacking. As such, alternative approaches that utilize commonly collected signals from cardiovascular assessment studies, such as electrocardiograms (ECG), to calculate respiration rate (RespRate) as a biomarker of potential adverse effects are becoming increasingly relevant. In this study, we implement three algorithms developed to estimate ECG-derived RespRate (EDR) in humans on preclinical ECG data collected from dogs. We then compare EDR to the benchmark direct measure of RespRate derived from telemetry intra-thoracic pressure (ITP) sensors in 19 recordings. EDR obtained using the moment-based and principal component-based algorithms was not significantly different from the benchmark, based on a TOST (two one-sided tests) analysis with an equivalence margin of five breaths/min, in 100% and 89% of animals respectively. Furthermore, in a positive control study administering Theophylline, the PCA method detected a drug-induced increase in RespRate also present in the ITP data. Thus, EDR may provide a potential alternative to stand-alone respiratory assays, but further evaluation across a broader range of respiration changes, subjects, and ECG hardware is needed to establish the robustness of these algorithms.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...