Related Experiment Video
Updated: Oct 24, 2026

Noninvasive Electrocardiography in the Perinatal Mouse
Published on: June 12, 2020
Antepartum electronic fetal monitoring interpretation: multicenter observational study
Paulino Vigil-De Gracia1, Colisandra Robledo Paz2, Cristobalina Campos Ávila3
1Complejo Hospitalario Dr. AAM (CSS), Hospital Materno Infantil, Ciudad de la Salud (CSS), Panama City, Panama. pvigild@hotmail.com.
Background:
Antepartum EFM is the most widely used method worldwide to evaluate fetal well-being. However, neither NST nor other surveillance techniques can precisely determine the onset or degree of fetal hypoxemia and acidemia. The presence of accelerations seems to reflect fetal well-being; however, their absence does not predict fetal compromise. Evidence regarding the perinatal prognosis of normal NSTs with one or no accelerations compared with those classified as reactive remains insufficient.
Objective:
To compare perinatal outcomes of the non-stress test (NST) interpreted by the usual reactive/non-reactive criterion versus the NST reported as "fetal well-being preserved" when there is one or no fetal heart rate (FHR) acceleration with moderate variability.
Methods:
Multicenter, non-randomized, observational, comparative non-inferiority study evaluating two different NST interpretation criteria, conducted in Panama among high-risk pregnant patients with ≥ 34 weeks' gestation. A reactive NST was defined as a tracing with baseline FHR 110-160 beats per minute, variability 6-25 [beats/min], no bradycardia, and at least two accelerations within 20 min. When one or no acceleration was present while the other criteria were maintained, the NST was defined as showing "fetal well-being preserved" (normal/reassuring).
Results:
We analyzed 1,206 NSTs from 699 patients. There were no significant differences in gestational age at birth, time elapsed since the first NST, mode of delivery, 1- and 5-minute Apgar scores, or the presence of variable decelerations. No perinatal death was associated with follow-up by NST report. Twelve cases (0.99%) were reported as abnormal at the second NST performed 7 days after the initial NST. In those cases, no perinatal deaths occurred; two cases had a 5-minute Apgar < 7, one in each reporting group. Across the entire population, there were 6 deaths with no significant differences related to the initial NST reporting category.
Conclusion:
This observational non-inferiority study reporting the NST as reactive (≥ 2 accelerations) or as fetal well-being preserved/reassuring (normal variability with ≤ 1 acceleration) yields no large differences in fetal well-being outcomes.
More Related Videos
05:15Amplitude-Integrated EEG in Infants at Risk of Hypoxic-Ischemic Encephalopathy: A Feasibility Study in Road and Air Transport in Western Australia
Published on: June 21, 2024
05:58Application of an Amplitude-integrated EEG Monitor (Cerebral Function Monitor) to Neonates
Published on: September 6, 2017