Related Experiment Video
Updated: Oct 24, 2026

NiO Nanoflowers for Non-Enzymatic Amperometric Detection of Glucose
Published on: December 30, 2025
Hierarchical Ni-rGO nanocomposite derived from e-waste graphite for trace-level electrochemical sensing of
Abdullah Ibn Masud Mubin1,2, Md Humayun Kabir3, Md Qamrul Ehsan2
1Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR) Dhanmondi Dhaka-1205 Bangladesh sabinayasmin@bcsir.gov.bd.
Abstract:
Metronidazole (MTZ) accumulation in aquatic systems presents severe environmental and public health risks, requiring sensitive trace-level monitoring techniques. Here, we report the development of an electrochemical sensor based on a reduced graphene oxide (rGO) nanocomposite decorated with nickel-containing nanophases (Ni-rGO). The graphene oxide support was synthesized from graphite sustainably recovered from discarded lithium-ion batteries prior to integration via a one-pot, hydrazine-free hydrothermal method. Morphological and structural analyses (SEM, TEM, XRD, FTIR) reveal a hierarchical architecture where highly dispersed, ultra-small (1.5-3 nm) nickel-containing domains coexist with larger crystalline domains anchored to a porous rGO network. This dual-scale structure likely prevents graphene restacking, resulting in a 41.2% increase in electrochemically active surface area and a 43.35% reduction in interfacial charge-transfer resistance compared to unmodified glassy carbon electrodes. Voltammetric studies demonstrate that MTZ reduction at the Ni-rGO interface proceeds via a diffusion-dominated, proton-coupled electron transfer mechanism at physiological pH (7.4). Under optimal conditions, the sensor exhibits a wide linear range of 2-200 µM, a low detection limit of 122.6 nM, and a high sensitivity of 5111.9 µA mM-1 cm-2. The sensor exhibited high fabrication reproducibility (3.12% relative standard deviation across five independent electrodes), operational repeatability (95.4% signal retention over 10 continuous cycles), and storage stability (91.9% retention after 7 days). The analytical response remained unaffected by 10-fold excesses of common inorganic ions, endogenous biological species (dopamine, ascorbic acid, uric acid), and the structural analog imidazole, as well as 5-fold excesses of commonly used antibiotics, confirming the sensor's strict specificity toward the target analyte. Recovery rates of 87-108% across tap water and human urine matrices confirm the practical analytical utility of the Ni-rGO sensor for real-world MTZ monitoring in both environmental and clinical contexts.
More Related Videos
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016