Related Experiment Video
Updated: Oct 24, 2026

Models and Methods to Evaluate Transport of Drug Delivery Systems Across Cellular Barriers
Published on: October 17, 2013
Barrier model selection alters apparent diclofenac permeation parameters: a controlled in vitro comparison of
Filip Dugonik1, Urška Jeršič1, Lejla Kač1
1Institute of Biomedical Sciences, Faculty of Medicine, University of Maribor, Maribor, Slovenia.
Introduction:
Synthetic membranes and keratinocyte-based constructs are both used as accessible alternatives to ex vivo skin in in vitro permeation testing (IVPT), but they have not been compared directly for the same marketed products under identical conditions. This pilot study directly compared the synthetic Strat-M® membrane and a HaCaT construct under identical IVPT conditions using Voltaren® and Olfen®, two marketed, nominally dose-equivalent diclofenac gels. The aim was to determine whether the two barrier models yielded consistent apparent permeation parameters and led to the same comparative interpretation of the two formulations.
Methods:
Permeation studies were performed using Franz diffusion cells in an internally controlled experimental design. Both formulations were tested in triplicate under identical conditions, including receptor medium, temperature, sampling protocol, and analytical method. Steady-state flux (Jss), permeability coefficient (Kp), lag time (tlag), and cumulative permeation profiles were determined and compared between barrier models.
Results:
Barrier model selection affected the apparent permeation behavior of diclofenac. Strat-M® detected a statistically significant difference in steady-state flux between Voltaren® and Olfen®, whereas no statistically significant between-formulation difference was detected with the HaCaT construct under the same experimental conditions. Lag time was the parameter most strongly influenced by barrier selection and was consistently shorter with the HaCaT construct than with Strat-M®.
Discussion:
Under identical IVPT conditions, Strat-M® and the HaCaT-based epidermal construct generated different apparent permeation profiles and yielded different comparative assessments of Voltaren® and Olfen®. This model-dependent divergence underscores the need to justify barrier selection explicitly and to consider its limitations when interpreting comparative IVPT data.
More Related Videos
Related Concept Videos
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Pharmacodynamic Models: Direct Effect Model and Indirect Response Model
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Physiological Pharmacokinetic Models: Incorporating Hepatic Transporter-Mediated Clearance
A recent model describes pravastatin's hepatobiliary excretion, mediated...
Hepatic Drug Clearance: Role of Transporters
Physiological Barriers
The blood endothelial barrier is the most porous of these. It allows all small ionized, un-ionized, and lipophilic molecules to pass through the endothelial lining into the interstitial space...