Abstract:
Acute aortic syndrome (AAS) is a time-critical vascular emergency in which delayed recognition may occur because the presenting symptoms and electrocardiographic phenotypes often overlap with acute coronary syndrome, pulmonary embolism, pericarditis, and other emergency diagnoses. Computed tomographic angiography (CTA) remains the confirmatory standard, but the 12-lead electrocardiogram (ECG) is usually obtained earlier, is universally available at triage, and may carry distributed signatures of malperfusion, ischemia mimicry, autonomic stress, conduction delay, and hemodynamic compromise. We developed Q-AortaECG, a classically implemented quantum-inspired multi-agent ECG system that integrates multiscale waveform representations, specialist ECG agents, density-state uncertainty fusion, a variational-circuit style consensus layer, and a safety-gated multidisciplinary team-style report for early AAS triage. The system was evaluated in three suspected-AAS/CTA-evaluable cohorts comprising 1,251 patients, including 467 with CTA-, surgery-, or autopsy-confirmed AAS. Across 700 locked-test patients, Q-AortaECG achieved an area under the receiver operating characteristic curve (AUROC) of 0.881 (95% confidence interval (CI), 0.852-0.908), area under the precision-recall curve (AUPRC) of 0.743 (95% CI, 0.695-0.790), sensitivity of 0.955 (231/242; 95% CI, 0.920-0.977), specificity of 0.721 (330/458; 95% CI, 0.677-0.761), positive predictive value (PPV) of 0.643, and negative predictive value (NPV) of 0.968 at the prespecified high-sensitivity threshold. Performance remained consistent in external retrospective validation and prospective silent-run evaluation, although AUPRC decreased in the lower-prevalence prospective cohort. Ablation experiments supported the contributions of self-supervised ECG pretraining, agent specialization, density-matrix uncertainty fusion, and differential diagnosis modeling. In a counterbalanced paired reader study, Q-AortaECG assistance improved overall clinician sensitivity from 0.696 to 0.870 while preserving specificity (0.851 ver sus 0.846). In prospective silent-run analysis, counterfactual alerts would have advanced the median time to the correct diagnostic pathway from 187 to 61 minutes among initially unsuspected AAS presentations. These findings support ECG first, calibrated, safety-gated decision support as an early warning scaffold for AAS triage, while preserving CTA and expert imaging interpretation as the diagnostic standard.
More Related Videos
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Cardiopulmonary Resuscitation IV: Pharmacological Management
Acute Coronary Syndrome III: Diagnostic Studies
Aortic Regurgitation I: Introduction
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...