Related Experiment Video
Updated: Oct 25, 2026

Multimodal Analysis of Microplastics in Drinking Water using a Silicon Nanomembrane Analysis Pipeline
Published on: June 13, 2025
A framework for assessing human internal microplastic exposure through dataset alignment and quality screening
A A Koelmans1, Y Qiu1, I Wardani1
1Aquatic Ecology and Water Quality Management Group, Wageningen University and Research, Droevendaalsesteeg 3, 6700 AA Wageningen, Netherlands.
Abstract:
Determining human microplastic exposure from external intake estimates combined with biodistribution modelling remains highly uncertain because errors propagate across multiple pathways and assumptions. We therefore present a framework for estimating internal human microplastic exposure directly from published measurements in organs, tissues, and bodily fluids. The framework integrates dataset selection, QA/QC screening, and an updated mathematical alignment method incorporating statistical fitting, goodness-of-fit testing, and comparison of alternative particle-size distributions to support cross-compartment comparison and whole-body inference. As a proof of principle, we applied this approach to published human microplastic particle data under two scenarios: an 'as measured' scenario and a 'biologically plausible' scenario in which particle size distributions were truncated at literature-based accessibility limits. The scenarios produced strongly divergent mean estimates: 159.4 mg (80.9-824; parametric 95 % Monte Carlo interval) under the 'as measured' scenario and 0.41 mg (0.22-1.56; parametric 95 % Monte Carlo interval) for the truncated 'biologically plausible' scenario. This 388-fold divergence shows that current quantitative inference is dominated by assumptions about the treatment of unusually large particles and data quality. The values should therefore be interpreted as scenario-bounded framework outputs conditional on the currently available, clinically biased dataset, and not as estimates representative of healthy populations or the general population. The framework also yielded apparent, size-dependent organ-to-blood ratios that may serve as provisional benchmarks or hypothesis-generating boundary conditions for future physiologically based kinetic (PBK) model development, but not yet as validated tissue-partitioning constants. Although current data quality limits regulatory-grade quantification, the framework provides a transparent basis for exposure assessment using human monitoring data, for identifying key uncertainties, and for illustrating potential future regulatory application.

