Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
A Wearable Ultrasound Sensor for the Simultaneous Assessment of Hemodynamics and Blood Pressure
Xingqi Li1, Sijing Zhu2, Hao Wang3
1State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin150001, China.
Abstract:
Cardiovascular disease remains a major global health burden, and monitoring vascular information is crucial for the management of cardiovascular disease in daily life. However, existing wearable technologies suffer from limitations such as poor signal quality, limited sensing modalities, and low accuracy. Here, we propose a wearable ultrasonic array patch system comprising 64 elements to overcome the above difficulties and be used for tracking blood dynamics and blood pressure fluctuations. Guided by finite-element piezoelectric simulations, the size of the ultrasonic array was designed. Additionally, the patch utilizes a hydrogel material to ensure proper coupling with the skin. Testing revealed that the patch achieves a -6 dB bandwidth of 71% and a peak-to-peak received voltage of 0.22 V. The patch achieves a high spatial resolution of 0.96 mm × 0.60 mm at a detection depth of 15 mm. The system employs two key approaches to acquire physiological information. The first is a multimodal acquisition scheme capable of simultaneously capturing relative blood pressure trends and hemodynamic characteristics. The second is an angle-dependent reduced vector Doppler framework that utilizes multi-angle beams to calculate blood flow vectors. This work builds on existing wearable ultrasound devices and establishes a platform for the continuous assessment and monitoring of vascular hemodynamics.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: