Related Experiment Video
Updated: Oct 25, 2026

Separation of Uranium and Thorium for 230Th-U Dating of Submarine Hydrothermal Sulfides
Published on: May 20, 2019
Capsule-Type Hydrothermal Extraction-Coupled NanoESI-MS/MS for Analysis of Uranium Isotope in Sub-milligram Lunar
Lili Song1, Yongpeng Liu1, Chun Wan1
1Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang330013, P. R. China.
Abstract:
Uranium concentration and isotopic data from returned extraterrestrial materials provide constraints on planetary differentiation, thermal evolution, and chronological frameworks. However, the extreme paucity of such specimens demands analytical methodologies capable of analysis at ultratrace sample amounts. Herein, we report an integrated workflow coupling capsule-type hydrothermal extraction (CTHE) with nanoelectrospray ionization tandem mass spectrometry (nanoESI-MS/MS) for the determination of uranium isotope in sub-milligram lunar regolith. Leveraging the hydrostatic pressure balancing strategy, sub-milligram samples were hydrothermally digested within a polytetrafluoroethylene micro-capsule using HF/HNO3 at high-temperature and high-pressure conditions. Following controlled elimination of residual acids, uranium was converted to the [UO2(NO3)3]- complex and analyzed by nanoESI-MS/MS in the negative ion mode via selective reaction monitoring of the characteristic transitions m/z 456.0 → 410.0 (238U) and m/z 453.0 → 407.0 (235U). The optimized method affords a limit of detection of 0.63 μg/L, a linear dynamic range spanning 0.01-2.00 mg/L (R2 > 0.99), a sample consumption as low as 0.1 mg, and spike recoveries of 92.4-97.4% with relative standard deviations (RSDs) < 4% (n = 3). Application of the CTHE-nanoESI-MS/MS method to Chang'e-5 lunar regolith afforded a uranium concentration of 1.44 ± 0.06 μg/g and a 235U/238U ratio of 0.007198 ± 0.000102 (RSD = 1.42%, δ = -8.13‰ relative to the certified natural uranium value). Notably, this approach reduces sample consumption by two orders of magnitude relative to conventional hydrothermal digestion combined ICP-MS detection methods. This methodology establishes an analytical paradigm for uranium isotope geochemistry in sample-limited materials.
More Related Videos
14:53In Situ Detection and Single Cell Quantification of Metal Oxide Nanoparticles Using Nuclear Microprobe Analysis
Published on: February 3, 2018
09:23Removal of Trace Elements by Cupric Oxide Nanoparticles from Uranium In Situ Recovery Bleed Water and Its Effect on Cell Viability
Published on: June 21, 2015