Non-Target Analytical Workflow for Gas-Phase Atmospheric Chemicals Collected on XAD Resin and Application to Passive
Jenny Oh1,2, Adrià Sunyer-Caldú3,4, Chubashini Shunthirasingham5
1Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, OntarioM1C 1A4, Canada.
Abstract:
The atmospheric gas phase is underrepresented in non-target screening of environmental organic chemicals, partly due to limited evidence on sorbent suitability. Here, we developed a workflow for non-target analysis (NTA) of styrene-divinylbenzene copolymeric (XAD) resin-based air samples that involves both gas (GC) and liquid chromatography (LC) high-resolution mass spectrometry (HRMS). More than 60 000 features were detected in passive air samplers (PAS) deployed over 4-48 weeks. Of ∼34 000 features retained after blank filtration, ∼14 000 (41%) showed an increasing signal with deployment time, suggesting that they represent substances with volatility and degradability sufficiently low for accumulation on XAD without substantial re-evaporation or degradation during the prolonged sampling period. Such linear uptake is a prerequisite for comparing PAS-derived signals across deployments and chemical classes. Chemical identification by reference standards (level 1) and spectral library matching (level 2) initially identified/annotated 116 compounds, many of which were bioactive and/or brown carbon species. Combining advanced downstream computational workflows of feature-based molecular networking (FBMN) and in silico prediction (Network Annotation Propagation/MetFrag) allowed for the structural annotation (level 3) of >8300 LC-HRMS features, including several compounds of natural and anthropogenic origin which were not previously reported in the atmospheric gas phase. Several long-chain fatty acids showed rapid early increases implausible with atmospheric origins and are likely to originate from microbial growth on the resin. Overall, our results demonstrated that XAD is a sorbent compatible with comprehensive NTA and suitable for time-integrated passive sampling of a diverse range of gas-phase organic chemicals from the atmosphere.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...