Related Experiment Video
Updated: Oct 25, 2026

A Microfluidic Flow Chamber Model for Platelet Transfusion and Hemostasis Measures Platelet Deposition and Fibrin Formation in Real-time
Published on: February 14, 2017
Time-Dependent UV/Ozone Treatment Modulates Platelet Adhesion on Polystyrene and Cyclo-Olefin Polymer through
Riko Kaizu1, Aki Yamamoto2, Masaru Tanaka2
1Department of Materials Science and Engineering, School of Materials and Chemical Technology, Institute of Science Tokyo, Yokohama226-8502, Japan.
Abstract:
UV/ozone (UVO) treatment is a versatile, solvent-free approach for modifying polymer surfaces in biomedical applications. Although its effects on RGD-dependent cell adhesion have been extensively studied, the mechanisms underlying non-RGD-dependent interactions, specifically platelet adhesion, remain poorly understood. In this study, we investigated the adhesion and activation of human platelets on polystyrene (PS) and cyclo-olefin polymer (COP) surfaces modified with 172 nm vacuum ultraviolet (VUV) light-induced UVO treatment. A distinctive non-monotonic relationship between UVO irradiation time and platelet response was observed: short-term treatment (1-2 min) maximized platelet density, with a substrate-dependent increase in platelet activation that was most pronounced on PS, whereas prolonged treatment (>10 min) slightly reduced platelet density compared to short-term treatment. Surface analyses by X-ray photoelectron spectroscopy (XPS), water contact angle (WCA), and atomic force microscopy (AFM) showed monotonic increases in oxygen content, hydrophilicity, and nanoscale roughness, and were accompanied by a two-orders-of-magnitude decrease in Young's modulus (from approximately 1500 MPa to 10 MPa). Quartz Crystal Microbalance with Dissipation (QCM-D) measurements of fibrinogen (Fg) adsorption indicated that short-term treatment promotes a "side-on" orientation of Fg, maximizing the exposure of γ-chain binding sites relevant to platelet integrin recognition. In contrast, long-term treatment leads to a crowded interfacial environment, likely disrupting stable protein presentation. Furthermore, excessive surface softening may impair platelet mechanosensing. These findings provide mechanistic insight into time-dependent UVO surface modification and offer a rational framework for optimizing the hemocompatibility of polymer-based medical devices.
Related Concept Videos
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...
Clot Retraction and Fibrinolysis