Related Experiment Video
Updated: Oct 25, 2026

Uncovering Beat Deafness: Detecting Rhythm Disorders with Synchronized Finger Tapping and Perceptual Timing Tasks
Published on: March 16, 2015
Group Differences in Reported Jitter and Shimmer Are Partly Associated with the Harmonics-to-Noise Ratio
Oğuzhan Aydemir1, Gökhan Aydemir2
1Nişşı University, Istanbul, Turkiye.
Objectives:
Jitter and shimmer are often compared between groups that also differ in the harmonics-to-noise ratio (HNR). This study examined how much of a reported group difference in these measures is associated with the HNR difference rather than with a difference in cycle-to-cycle perturbation.
Study Design:
Retrospective analysis of an existing database against a simultaneously recorded electroglottographic (EGG) reference.
Methods:
Sustained /a/, /i/, and /u/ at normal pitch and /a/ at low and high pitch were analyzed from the Saarbrücken Voice Database (1554-1734 speakers per condition, one recording per speaker). Reference jitter was computed from glottal closure instants detected in the EGG signal; acoustic jitter, shimmer, and HNR were obtained with Praat. In Experiment 1, groups were matched on EGG-derived reference jitter and fundamental frequency (f0) and differed in HNR. In Experiment 2, groups were matched on HNR and differed in reference jitter. In Experiment 3, groups were formed on reference jitter without matching.
Results:
In Experiment 1 (/a/, normal pitch), an HNR difference of 6.55 dB was accompanied by a reported jitter difference of -0.257% points (pp) (95% CI -0.305 to -0.208; d = -0.63), whereas the reference jitter difference was -0.079 pp (95% CI -0.167 to 0.010). The effect was present in all five conditions, persisted after adjustment for sex, age, recording type, recording level, duration, and spectral balance (-0.214 to -0.289 pp), appeared in a second jitter implementation, and increased with the HNR gap (-0.043 pp/dB; 95% CI -0.050 to -0.027). With HNR matched, 18-34% of a reference jitter difference appeared in the reported value. A synthetic control indicated an HNR-associated shimmer difference of -1.06 pp (95% CI -1.35 to -0.76).
Conclusions:
In this database and implementation, between-group HNR differences were associated with reported jitter and shimmer differences not accounted for by the EGG reference, while reference differences were attenuated. The design was observational, and the groups also differed in recording level and spectral balance, so these findings are associations rather than demonstrations that HNR itself produces the differences. Group comparisons of perturbation measures should be interpreted together with the accompanying HNR difference.
Related Concept Videos
Harmonic Mean
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Expected Frequencies in Goodness-of-Fit Tests
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Concept of Resonance and its Characteristics
