Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Optimal depolarization sequence for cardiac resynchronization therapy patients
Ksenia Sedova1,2, Jan Azarov1, Peter M Van Dam3
1Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Sitna Sq. 3105, Kladno 272 01, Czech Republic.
Aims:
Electrical ventricular dyssynchrony is a hallmark of intraventricular conduction disease in heart failure with reduced ejection fraction. Although cardiac resynchronization therapy (CRT) is effective, a proportion of patients with electrical dyssynchrony evidenced by an electrocardiogram (ECG) remain non-responders. Besides the QRS duration, visualization and quantification of the depolarization sequence could contribute to improving CRT response. The study aimed to evaluate the CineECG-derived mean temporo-spatial isochrone trajectory of depolarization in CRT patients.
Methods And Results:
Among the adult cohort of 121 patients who underwent CRT implantation, there were 93 (33% female) responders and 28 (7% female) non-responders. ECGs recorded before and immediately after CRT implantation were collected and analysed using the CineECG modality with a generic heart/torso model. The CineECG-derived path directions were computed for the QRS on anteroposterior, interventricular, and apicobasal axes within the cardiac anatomy. Spatial depolarization characteristics were tested for the association with left ventricle reverse-remodelling at 6-month follow-up. The pre-implantation depolarization sequence was predominantly from the right to the left ventricle, and after the CRT implant, it has been transformed into an apicobasal direction. In multivariate logistic regression, the pre-implant QRS duration, apicobasal depolarization gradient, and CRT-induced QRS shortening independently predicted CRT response. The Akaike information criterion indicated that combining all three yielded the strongest predictive model.
Conclusion:
CineECG-derived depolarization gradients, which reflect ventricular activation sequence, changed significantly after CRT, and the pre-implantation apicobasal gradient independently predicted echocardiographic outcome, with a less pronounced gradient associated with better haemodynamic response.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrophysiology of Normal Cardiac Rhythm
Dysrhythmias VI: Management of Dysrhythmias
Cardiopulmonary Resuscitation IV: Pharmacological Management
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiopulmonary Resuscitation III: AED Use