Related Experiment Video
Updated: Oct 26, 2026

Combined Supine and Standing Imaging for Varicocele: An Improved Diagnostic Approach
Published on: November 22, 2024
Three and Two Dimensional Saline Infusion Sonohysterography in Diagnosing Uterine Cavity Lesions
Mina Jafarabadi1, Mitra Alizadeh1, Elahe Rezayof1
1Vali-E-Asr Reproductive Health Research Center, Family Health Research Institute, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.
Objective:
Given the invasive and costly nature of reference diagnostic methods like hysteroscopy , this study aimed to compare the diagnostic accuracy and the dimensional measurement agreement of uterine cavity lesions between two-dimensional saline infusion sonography (2D SIS) and three-dimensional saline infusion sonography (3D SIS) against the gold standard of hysteroscopy and histopathology.
Materials And Methods:
This cross-sectional study was conducted on 283 female patients who were candidates for hysteroscopy. Prior to surgery, all patients underwent blinded evaluations via 2D SIS and 3D SIS performed by experienced radiologists, and the type, number, location, and size of the lesions were recorded. Subsequently, all patients underwent diagnostic hysteroscopy and tissue sampling for pathological evaluation as the gold standard. Diagnostic performance metrics were calculated, and the dimensional agreement of the lesions between the modalities was statistically evaluated using the Intraclass Correlation Coefficient (ICC) and Bland-Altman analysis.
Results:
The mean age of the patients was 35.9 ± 8.1 years. Histopathological examination confirmed endometrial polyps in 20.5% and leiomyomas in 17.3% of the patients. Compared to 2D SIS, 3D SIS demonstrated higher sensitivity (83.15% vs. 78.65%), higher specificity (93.30% vs. 91.75%), and higher overall diagnostic accuracy (90.11% vs. 87.63%). In the dimensional agreement analysis, 3D SIS showed an excellent correlation (ICC = 0.927) and a negligible mean systematic error (mean bias: -0.26 mm; 95% limits of agreement: -7.77 to 7.25 mm) compared to hysteroscopy. In contrast, 2D SIS systematically overestimated lesion dimensions compared to hysteroscopy (mean bias: 2.21 mm) and exhibited the widest limits of agreement when compared with 3D SIS (-8.76 to 13.70 mm).
Conclusion:
3D SIS is an accurate, non-invasive tool that lacks systematic bias in measuring uterine tumors, offering superior performance compared to the 2D SIS method. Given its high overall accuracy, 3D SIS can be utilized as a reliable first-line diagnostic tool, significantly reducing the necessity for unnecessary diagnostic hysteroscopies and the associated financial burdens on the healthcare system.
Related Concept Videos
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies VI: Voiding Cystourethrography and Cystography
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
