Related Experiment Video
Updated: Oct 26, 2026

Finite Element Modeling for the Simulation of the Quasi-Static Compression of Corrugated Tapered Tubes
Published on: January 6, 2023
Mechanical properties of bidimensional T-loop closing springs compared with conventional T-loops: A 3-dimensional
Necati Turkmen1, Gulnaz Marsan2
1Department of Orthodontics, Faculty of Dentistry, Istanbul Aydin University, Istanbul, Turkey.
Introduction:
T-loop closing springs are widely used for extraction space closure in friction-free orthodontic mechanics. The bidimensional technique exploits differential wire-slot engagement to enhance anterior torque control; however, its application to T-loop design has not been investigated. This study aimed to compare the 3-dimensional force systems produced by conventional and bidimensional T-loop closing springs across different interbracket distances and activation levels using finite element analysis.
Methods:
Six 3-dimensional T-loop models were constructed using SolidWorks 2021 (Dassault Systèmes, Vélizy-Villacoublay, France): 3 conventional and 3 bidimensional designs made from 0.016 × 0.022-in stainless steel wire, each modeled at interbracket distances of 6, 8, and 10 mm. All models assumed a 0.022-in bracket slot. The bidimensional variant incorporated a 90° torsion bend at the loop's midportion. Static structural analysis was performed in ANSYS 2021 R2 (ANSYS Inc, Canonsburg, Pa) with cinch-back activations of 2 mm and 4 mm. Digital sensor probes recorded forces and moments at both wire ends along 3 spatial axes.
Results:
Bidimensional T-loops consistently generated higher horizontal forces and moments than conventional designs. With 2-mm activation at a 6-mm interbracket distance, the alpha-end horizontal force was 3.29 N in the bidimensional design compared with 2.52 N in the conventional design (∼30% increase). Alpha-end moment-to-force ratios ranged from 4.14-5.58 mm for the bidimensional design vs 3.95-5.11 mm for the conventional design. The 90° torsion bend reduced alpha bracket-slot angular clearance from 3.8° to 0.95°.
Conclusions:
Based on theoretical finite element predictions, the bidimensional T-loop design produces greater forces, moments, and alpha-end moment-to-force ratios than conventional T-loops. Reduced alpha-end bracket-slot play may reduce moment attenuation, offering potential biomechanical advantages for maximum-anchorage retraction. These are theoretical mechanical predictions that require clinical and experimental validation before definitive conclusions can be drawn.
Related Concept Videos
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Euler's Formula to Columns: Problem Solving
The system comprises two vertical rigid bars, AB and BC, of...
Torsion of Noncircular Members
Thin-Walled Hollow Shafts
Stress Concentrations in Circular Shafts
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...

