Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
Published on: March 24, 2023
Flexible Piezoresistive Yarn Pressure Sensor for Arterial Blood Pressure Waveform Measurement
Rizal Maulana1, Ádám Rák1, Sándor Földi1
1Faculty of Information Technology and Bionics, Pázmány Péter Catholic University, Práter u. 50/A, 1083 Budapest, Hungary.
Abstract:
The arterial blood pressure (ABP) waveform contains essential information concerning the hemodynamic status and its relation to the diagnosis of cardiovascular conditions. Therefore, the continuous monitoring of the ABP waveform has become important. The arterial cannula, considered the gold standard for this monitoring, carries a risk of vascular trauma due to its invasive nature. Consequently, a measurement system that offers a non-invasive approach and maintains high accuracy in detecting morphological details of the ABP waveform is needed. In this study, we introduce a flexible piezoresistive yarn (FPY) pressure sensor for continuous non-invasive ABP waveform measurement. The sensor was experimentally validated using two scenarios: measurements on a hardware simulator and at a radial artery site. The simulator measurement aimed to assess the sensor's performance in detecting consistent waveforms, while the radial artery site measurements evaluated the sensor's performance in measuring ABP waveforms corresponding to the cardiovascular cycle. The simulator measurement results showed high repeatability, reproducibility, and accuracy relative to the reference signal at the upper limit of realistic force magnitude, as measured by the Pearson correlation coefficients: 0.9999 ± 0.0002 (10 measurements), 0.9994 ± 0.0002 (3 measurements), and 0.9731 ± 0.0027 (10 measurements), respectively. The correlation value derived from measurements at the radial artery site compared with measurements using a 3D force sensor as a reference sensor was 0.9880 ± 0.0035 (10 measurements from a single subject). Based on our results, the FPY pressure sensor can be used as an innovative solution for monitoring ABP waveforms and has further potential to be developed as a diagnostic device for evaluating cardiovascular conditions.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: