Related Experiment Videos
CT-Referenced Diagnostic Performance and Complementary Error Patterns of Artificial Intelligence Versus a Single
1Department of Emergency Medicine, Faculty of Medicine, Mardin Artuklu University, 47200 Mardin, Türkiye.
Abstract:
Background/Objectives: Artificial intelligence (AI) is increasingly used to support chest radiograph interpretation, but its clinical value depends not only on stand-alone accuracy but also on whether its errors differ from those of clinicians. We evaluated CT-referenced, target-specific diagnostic performance and complementary error patterns of a commercial chest radiograph AI system and a single emergency physician. Methods: In this retrospective, single-center, paired diagnostic accuracy study, 920 consecutive adults who underwent posteroanterior chest radiography and thoracic computed tomography (CT) within 4 h during the same emergency department encounter were included. A commercial AI system (hChestXR version 1) and a single blinded emergency physician independently assessed eight prespecified thoracic findings using CT as the reference standard. Paired differences were estimated with 10,000 patient-level bootstrap resamples and tested with exact McNemar tests with Holm adjustment. Exact-target complementarity and simulated same-target OR/AND rules were secondary exploratory analyses. Results: Across 7360 patient-target assessments, including 1232 CT-positive findings, AI had significantly greater Holm-adjusted sensitivity for pneumothorax (90.8% vs. 50.8%), nodule/mass (63.3% vs. 32.7%), and rib fracture (77.2% vs. 46.5%). AI-only detections were most frequent for pneumothorax (47.7%), nodule/mass (44.9%), and rib fracture (43.6%), whereas physician-only detections were most frequent for atelectasis (24.8%), pulmonary edema (21.0%), and lung opacity (19.7%). In exploratory pooled analyses, sensitivity was 73.0% for AI and 62.0% for the physician. Exploratory simulated same-target OR/AND analyses demonstrated a sensitivity-specificity trade-off across pooled patient-target assessments but did not represent observed AI-assisted clinical performance. Conclusions: The AI system and the single emergency-physician reader in the study showed target-dependent, partly non-overlapping error patterns in this CT-selected emergency cohort. The findings support prospective multireader evaluation of AI as a second-reader tool but do not establish benefit from real-time AI-assisted interpretation.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...