A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Relationship Between Pulse Oximetry and Arterial Oxygen Saturation During Rest and Exercise at Extreme Altitude
Giorgio Manferdelli1,2, Denis J Wakeham1,2, Keval D Patel1,2
1Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital Dallas, Dallas, Texas, USA.
Abstract:
Manferdelli, Giorgio, Denis J. Wakeham, Keval D. Patel, Eric T. Hedge, Michael G. Leahy, Abel Thomas, James Berry, Tony G. Babb, Peter Hackett, Renie Guilliod, Benjamin D. Levine, Christopher M. Hearon, Jr., and Andrew R. Tomlinson. Relationship between pulse oximetry and arterial oxygen saturation during rest and exercise at extreme altitude. High Alt Med Biol. 00:00-00, 2026.
Introduction:
Pulse oximetry (SpO2) is commonly used to guide oxygen use, including at high altitude, but its accuracy during severe hypoxemia remains uncertain. This study aimed to compare arterial oxygen saturation (SaO2) and SpO2 while using graded levels of supplemental oxygen at simulated extreme altitude in a hypobaric chamber.
Methods:
Four healthy, unacclimatized adults completed rest and 60 Watts of exercise at different flow rates of supplemental oxygen (6, 4, 2, 1, and 0 l/min nominal flow) at 282 mmHg barometric pressure (Pb; equivalent to 8,100 m) and 253 mmHg Pb (equivalent to 8,848 m) with simultaneous measurement of arterial blood gases (radial artery catheter) and SpO2 (forehead pulse oximetry). Exercise was only performed at 282 mmHg.
Results:
Across all altitudes and conditions, SaO2 and SpO2 demonstrated a very strong correlation (all r2 ≥ 0.95, p < 0.001), with SpO2 showing a consistent positive bias (pooled: 1.7% [-4.4% to 7.7%]; 282 mmHg rest: 0.4% [-4.5% to 5.3%]; 282 mmHg exercise: 3.1% [-2.2% to 8.5%]; 253 mmHg rest: 2.9% [4.9% to 10.6%]). The magnitude of the SpO2 bias was higher when only SaO2 <70% was considered (pooled: 5.2%). The root mean square error was 2.6 for SaO2 ≥70% and increased to 6.2 when SaO2 was <70%.
Conclusions:
Although SpO2 represents a precise noninvasive measure for SaO2 across a wide range of oxygen saturations (70%-100%), SpO2 has lower precision and accuracy during severe hypoxemia (<70% SaO2).
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Factors Affecting Respiration
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...