Quality-Aware Pulse Rate Classification and Rhythm Recognition Method for Improved PPG-Based Blood Pressure Analysis
Yalagala Sivanjaneyulu1, M Sabarimalai Manikandan2, Srinivas Boppu1
1School of Electrical and Computer Sciences Indian Institute of Technology Bhubaneswar Odisha India.
Abstract:
In this paper, we propose a photoplethysmogram (PPG) signal quality-aware pulse rate (PR) classification and rhythm (regular/irregular) recognition framework. The proposed method comprises preprocessing, PPG signal quality assessment (PPG-SQA), systolic peak detection and decision rules. In this study, we collected a wide variety of normal and abnormal PPG signals from standard PPG databases. Further, the PPG signals are recorded with various sensors and subjects to validate the accuracy and robustness of the method under intra-subject, inter-subject and sensor variability. Evaluation results demonstrate that the average peak-to-peak interval ( )-based PR classification method had a higher accuracy (bradycardia [BC]: 100%, normal: 99.31%, tachycardia [TC]: 95.68% for normotension [NT] blood pressure [BP] class PPG segments) as compared to the counting approach-based PR classification method. Results further showed that the rhythm recognition method with a 4 bpm threshold outperformed, achieving a sensitivity (SE) of 99.89%, specificity (SP) of 99.33% and accuracy (ACC) of 99.80%. To reduce false alarms, we present four PPG-SQA approaches to explore a lightweight and best PPG-SQA with higher SE for detecting noise-free PPG signals. Results demonstrated that the quality-aware PR classification and rhythm recognition methods can improve the trustworthiness of cardiac arrhythmia recognition and BP analysis while reducing false alarms and computational power by discarding noisy PPG signals, which are unavoidable in continuous and long-term health monitoring.
Related Concept Videos
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Regulation of Pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Pulse
The pulse serves as a clinical indicator...