Related Experiment Video
Updated: Oct 28, 2026

Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Rapid identification of marijuana using copper-phosphine ion complexation and commercialized paper spray
Alleigh N Couch1, Christopher M Zall2, J Tyler Davidson1
1Department of Forensic Science, Sam Houston State University, Huntsville, TX, USA. jtdavidson@shsu.edu.
Abstract:
Regulatory changes enacted through the 2018 Agriculture Improvement Act established the distinction between legal hemp and illicit marijuana based on a 0.3% Δ9-tetrahydrocannabinol (Δ9-THC) dry-weight threshold, reshaping analytical requirements for forensic laboratories. The influx of cannabis submissions and the quantitative requirements for marijuana identification have contributed to controlled substance backlogs and operational strain, prompting the adoption of more conservative semi-quantitative 1% decision-point methodologies. Differentiating hemp and marijuana is further complicated by the isomeric nature of Δ9-THC and cannabidiol (CBD), often requiring time-intensive chromatographic methods, including gas chromatography and liquid chromatography. This study provides a rapid, direct mass spectrometry approach for marijuana identification using copper-phosphine ion complexation and commercialized paper spray ionization-mass spectrometry (PSI-MS). Thirteen cannabinoids and a deuterated internal standard, Δ9-THC-d9, were characterized in the presence of [Cu(PPh3)2(ACN)2]BF4, generating characteristic copper-bound, oxidized cannabinoid species. A [Cu+2PPh3+Δ9-THC+O-2H]+ complex was observed at m/z 915, whereas CBD did not form an observable complex, thereby eliminating CBD interference for Δ9-THC quantitation. A semi-quantitative 1% decision-point assay was established by fortifying cannabis samples with Δ9-THC-d9 at a 1% administrative threshold and determining whether the post-decarboxylation Δ9-THC content exceeds the 1% administrative threshold. Validation studies established selectivity, accuracy, precision, expanded uncertainty, carryover, and limit of detection. The validated method was applied to methanolic extracts of 36 decarboxylated authentic cannabis samples, resulting in a 94% corrected identification rate, with two misidentifications due to high cannabinol (CBN) concentrations. The developed method enables marijuana identification in approximately 4 minutes, enhancing laboratory throughput and potentially minimizing casework backlogs.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Rapid Identification of Pathogens
High-Performance Liquid Chromatography: Types of Detectors
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

