Related Experiment Video
Updated: Oct 28, 2026

Production and Analysis of Sporosarcina pasteurii Biocement Bricks Using Custom 3D-Printed Molds for Unconfined Compression Tests
Published on: March 7, 2025
Effects of a Self-Developed Composite Modifier on the Compressive Strength, Shrinkage Behavior, and Microstructure of
Dawei Ma1, Pengyi Wan1, Yong Huang2
1Nanchang Construction Investment Group Co., Ltd., Nanchang 330038, China.
Abstract:
Cement-stabilized macadam is widely used in pavement base layers but is susceptible to shrinkage-induced cracking. This study evaluated a self-developed composite modifier, designated DX-3, with the aim of improving volumetric stability while maintaining compressive strength. Mixtures with cement dosages of 4.0%, 4.5%, and 5.0% and DX-3 dosages of 0-2.0% were tested for unconfined compressive strength (UCS), drying shrinkage, temperature shrinkage, and microstructural characteristics using SEM and EDS. The UCS generally increased with DX-3 dosage up to 1.5% and then stabilized or slightly decreased. At 4.5% cement and 1.5% DX-3, the 7 d and 28 d UCS reached 5.67 and 7.43 MPa, respectively. Adding 1.5% DX-3 reduced the total drying shrinkage coefficient by 21.54-30.93%, the average temperature shrinkage coefficient by 2.71-3.72%, and the peak coefficient by 3.45-4.58%. The greatest temperature shrinkage sensitivity occurred at 0 to -10 °C. SEM observations indicated a more continuous cementitious matrix with more gel-like microstructural features after DX-3 modification. Overall, DX-3 improved shrinkage-related volumetric stability without compromising basic compressive strength.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Microcracking in Concrete
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Mortar Properties
Superplasticizers