Measuring the Mechanical Properties of Glass Fiber Reinforcement Polymer Composite Laminates Obtained by Different Fabrication Processes
Published on: June 30, 2023
Mechanical and Thermomechanical Performance Evaluation of CFRP Sandwich Structures with Additively Manufactured
Alexandru Ciubotariu1, Teodor-Adrian Badea1, Madalina Mustareata1
1Composite Materials Laboratory for Aeronautical Field, Romanian Research & Development Institute for Gas Turbines-COMOTI, 220D Iuliu Maniu Av., 061126 Bucharest, Romania.
Abstract:
This study experimentally evaluates how various 3D-printed gyroid core materials influence the mechanical and thermo-mechanical performance of lightweight carbon-fiber-reinforced polymer (CFRP) sandwich structures. Three gyroid core configurations were considered: short-carbon-fiber-reinforced polyphthalamide (PPA-CF), continuous-carbon-fiber-reinforced nylon (ONYX-R), and nylon short-carbon-fiber-reinforced (ONYX), all combined with similar 0/90° carbon-fiber-reinforced polymer composite (CFRP) face sheets. The sandwich specimens were manufactured using a one-step co-curing process and characterized by flatwise compression, three-point bending, and dynamic mechanical analysis (DMA). The PPA-CF-CFRP sandwich configuration exhibited the highest flexural performance, with a maximum flexural stress of 148-156 MPa, approximately 39% higher than that of ONYX-R-CFRP, and the highest mean compression modulus of approximately 87 MPa. However, ONYX-R-CFRP achieved the highest mean compressive strength of 12.84 MPa, compared with 11.85 MPa for PPA-CF-CFRP. These findings indicate that the mechanical response depends on the loading mode and is influenced by the combined effects of the thermoplastic matrix, carbon-fiber reinforcement architecture, and the resulting structural characteristics of the printed gyroid cores. DMA revealed that the PPA-CF-CFRP sandwich achieved a storage modulus of ~9 GPa at 30 °C, outperforming the ONYX-R-CFRP configuration by approximately 70%. Conversely, ONYX-R-CFRP exhibited the highest damping capacity, with a maximum tan δ of approximately 0.16, about 60% higher than the PPA-CF-CFRP configuration. The ONYX-CFRP sandwich configuration displayed the lowest mechanical and thermo-mechanical performance, demonstrating that the stiffness, deformation capacity, damping response, and temperature-dependent mechanical behavior of these sandwich structures can be tailored through the selection of the additively manufactured core configuration.
Related Concept Videos
Fiber Reinforced Concrete
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Design of Prismatic Beams for Bending
Non-destructive Tests for Concrete Strength