Related Experiment Video
Updated: Oct 28, 2026

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Experimental and Analytical Evaluation of Strengthening Techniques for Ultra-High-Performance Concrete Circular
Aref Abadel1, Hussein Elsanadedy1, Husain Abbas1
1Chair of Research and Studies in Strengthening and Rehabilitation of Structures, Department of Civil Engineering, College of Engineering, King Saud University, P.O. Box 800, Riyadh 12372, Saudi Arabia.
Abstract:
This study presents an experimental investigation to evaluate the effectiveness of four schemes for strengthening circular reinforced concrete (RC) columns. The columns were cast using ultra-high-performance concrete (UHPC). Ten RC columns, categorized into five groups including four strengthening schemes, were tested under concentric axial compression. The first group (G1) included the unstrengthened specimens (control specimens). Group G2 included specimens strengthened using two carbon fiber-reinforced polymer (CFRP) layers and 4Ø12 near-surface-mounted (NSM) steel rebars. Group G3 consisted of specimens strengthened using three CFRP layers. In group G4, a 3 mm thick steel tube was used for column jacketing. The specimens of group G5 were strengthened using UHPC jacketing reinforced with three welded wire mesh (WWM) layers and 4Ø8 longitudinal steel rebars. The fibers of CFRP layers in all schemes were oriented in the circumferential direction. The experimental results indicated that all strengthening schemes significantly increased ultimate load by 30% to 69% and initial stiffness by up to 130%. The G5 strengthening scheme (UHPC jacketing reinforced with WWM and 4Ø8 steel rebars) was most effective in enhancing load capacity and stiffness, while CFRP wrapping (G3) offered a superior balance of strength and ductility without increasing column dimensions, preserving post-peak integrity.
More Related Videos
Related Concept Videos
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating within the...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Impact Strength of Concrete
Non-destructive Tests for Concrete Strength
Reinforcements in Concrete
Design of Columns under an Eccentric Load