Related Experiment Video
Updated: Oct 28, 2026

Preparation of Carbon Fiber and Bamboo Fiber Reinforced Poly (butylene Adipate-co-terephthalate) Foams by Supercritical Carbon Dioxide Foaming
Published on: October 10, 2025
Flexural Behavior of Structural Foam Concrete with Hollow Polymer Spherical Fillers Under Thermal and Mechanical
Alexey N Beskopylny1, Ivan Panfilov2, Diana M Shakhalieva3
1Department of Transport Systems, Faculty of Roads and Transport Systems, Don State Technical University, 344003 Rostov-on-Don, Russia.
Abstract:
Creating low-density composite materials that can handle significant temperature changes and bending stress is a promising approach for building floating platforms. This study creates a numerical model and conducts an experimental analysis of foam concrete containing polymer spheres with different diameters and properties. Laboratory bending tests were performed on manufactured foam concrete samples containing 10 mm, 12 mm, 15 mm, 19.05 mm, and 20 mm diameter polypropylene spheres. To predict the thermophysical properties of a composite featuring structural foam concrete with embedded polymer spheres, a numerical model was developed in the Material Designer module as the first step. The resulting density, thermal conductivity, and specific heat dependences were used as input for subsequent numerical analysis in ANSYS under nonuniform temperature and bending loading, based on the nonlinear Menetrey-Willam model. By comparing load-displacement curves for different sphere sizes, the accuracy of the model in forecasting strength and deformation properties was established. The study revealed that the maximum equivalent von Mises stress was 3.3 MPa, indicating that the material operates in the elastic zone, but close to crack formation. The maximum displacement due to temperature differences was 0.087 mm, and the tensile stress in the longitudinal direction was σX = 0.18 MPa. This indicates that the composite performs satisfactorily under temperature differences from +4 °C to -60 °C. Patterns of failure of structural foam concrete specimens with polymer spheres under bending were analyzed, demonstrating that cracking starts in the lower chord of the tensile zone, weakened by the presence of the spheres.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Related Concept Videos
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Members Made of Elastoplastic Material
As the bending moment...
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Fiber Reinforced Concrete
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity