An Observer-Data-Path Decoupled Time-Domain ADC with Three-Stage Digital Background Calibration in 28 nm CMOS
Chuan Qin1, Bowen Liu1, Runqiao Wang1
1Faculty of Integrated Circuit, Xidian University, Xi'an 710071, China.
Abstract:
This paper presents an observer-data-path decoupled time-domain ADC with three-stage digital background calibration, designed and comprehensively verified through post-layout simulations in 28 nm CMOS for highly integrated micro-systems. In scaled nodes, the voltage-to-time converter front-end exhibits large-signal nonlinearity, while the time-to-digital converter (TDC) resolution drifts with PVT; conventionally these two errors are strongly coupled in the time domain, making concurrent calibration difficult. To break this coupling, the proposed observer-data-path decoupled architecture confines a single-bit pseudo-random dither to an observer path for error extraction and reconstructs the signal in a dither-free data path, thereby separating the calibration loops without degrading the SNDR. Building on this decoupling, a constant time-offset injection logic eliminates the gated ring oscillator-TDC dead-zone, and the three-stage calibration compensates the ADC gain error induced by TDC-resolution drift through VTC-gain tuning, regulates the non-integer dither ratio through Bang-Bang control, and suppresses the residual even- and odd-order nonlinearity through a dither-modulated threshold-crossing algorithm with EWMA-filtered LMS polynomial adaptation. In post-layout simulation at 1 GS/s, the calibration lifts the near-Nyquist SFDR from 50.3 to 67.0 dBc and the SNDR to 46.0 dB, and improves the INL to -0.15/+0.70 LSB. The design consumes 2.98 mW under nominal conditions and 3.89 mW at the worst-power PVT corner, corresponding to nominal and worst-case Walden FoMs of 18.3 and 23.9 fJ/conversion-step, respectively, within a 0.0024-mm2 core.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Operational Amplifiers
Inverting and Non-inverting OpAmps
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Cascaded Op Amps
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...