Related Experiment Videos
Cross-Plant Few-Shot Attack Recognition and Detection in Industrial Control Systems
Mohammed Almansour1, Iftikhar Ahmad1, Madini O Alassafi1
1Department of Information Technology, Faculty of Computing and Information Technology, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
Abstract:
Intrusion detectors for industrial control systems are trained on the few testbeds that provide labelled attacks and then applied to plants with different sensors and processes. This study evaluates bidirectional few-shot transfer between the SWaT and WADI water testbeds, with attack identities separated across episodic splits, chronologically separated detection streams, and no gradient updates on the target plant. Cross-plant recognition reached macro-F1 scores of 0.8625 for SWaT to WADI and 0.8528 for WADI to SWaT from five labelled windows per class, but a randomly initialised encoder of the same architecture did not differ detectably on identical episodes, so these values reflect the episodic task more than the transferred representation. Detection depended on the scoring rule and on the target plant. With SWaT as the target, replacing centroid scoring with a local-neighbourhood rule raised ROC-AUC from 0.402 to 0.742 and from 0.528 to 0.797 with an untrained encoder; as the normal reference grew from one to 500 windows, the local rule rose from 0.495 to 0.805 while the centroid fell to 0.397, consistent with the mean of multimodal normal operation lying between operating states. From SWaT to WADI, neither rule exceeded chance. Cross-plant results on these benchmarks should be reported against reference conditions that carry no transferred information.
Related Concept Videos
Control Systems: Applications
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The direction...
Control Systems
At the heart...
Defenses Against Pathogens and Herbivores
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal and...
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...