Related Experiment Video
Updated: Oct 28, 2026

Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Ferrite-Core Four-Quadrant Rotating Eddy Current Probe for Enhanced Subsurface Defect Detection of Any Orientation
Alessandro Sardellitti1, Federico Carere2, Angelo D'Aguanno3
1Department of Engineering and Science, Universitas Mercatorum, 00186 Rome, Italy.
Abstract:
Deep subsurface defect detection (due to the so-called skin effect) and sensitivity in the detection of any orientation defects remain two of the main challenges in Eddy Current Testing (ECT). Although low-frequency excitation increases the penetration depth of the induced eddy currents, it also reduces the intensity of the generated magnetic field, significantly degrading the inspection capability. Rotating eddy current probes overcome the dependence on defect orientation, but their performance remains limited for deep subsurface defects. This paper proposes a ferrite-core four-quadrant probe that combines orientation-independent inspection with magnetic flux concentration provided by ferrite cores integrated inside the excitation coils. The proposed probe is first investigated through finite element analysis and then experimentally validated through a direct comparison with the corresponding air-core configuration. Both numerical and experimental results demonstrate that the ferrite-core configuration systematically enhances the inspection capability, with improvements ranging from approximately 22% for shallow defects to over 100% for the deepest investigated ones. Moreover, the proposed probe successfully detects defects buried up to 6 mm below the inspected surface, whereas the corresponding air-core configuration fails under the same operating conditions. These results demonstrate the potential of ferrite-core integration for extending the applicability of REC probes to deep subsurface inspections.
More Related Videos
05:04Active Probe Atomic Force Microscopy with Quattro-Parallel Cantilever Arrays for High-Throughput Large-Scale Sample Inspection
Published on: June 13, 2023
12:18Co-localizing Kelvin Probe Force Microscopy with Other Microscopies and Spectroscopies: Selected Applications in Corrosion Characterization of Alloys
Published on: June 27, 2022
Related Concept Videos
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Magnetic Field Of A Current Loop
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Eddy Currents
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
Induced Electric Fields: Applications
Magnetic Field Due to Two Straight Wires