Related Experiment Video
Updated: Oct 28, 2026

Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
A LoRaWAN-Enabled Capacitive Sensor Network for Soil Moisture and Groundwater Monitoring
Saman Abdanan Mehdizadeh1, Jamal Mohammadi Moalezadeh2, Yiannis Ampatzidis3
1Department of Mechanics of Biosystems Engineering, Faculty of Agricultural and Rural Development, Agricultural Sciences and Natural Resources University of Khuzestan, Ahvaz 63417-73637, Khuzestan, Iran.
Abstract:
Water scarcity requires low-cost systems capable of continuously monitoring soil water and groundwater dynamics in agricultural fields. We developed a LoRaWAN-enabled sensing platform integrating a wire-based interdigital capacitive soil-moisture probe fabricated on a PMMA substrate and a U-shaped PTFE-insulated capacitive groundwater probe installed in a perforated PVC tube. Both sensors are interfaced with an ESP32 and communicate through 868 MHz LoRaWAN, with cloud-side calibration for soil moisture. Soil-moisture calibration against the gravimetric reference at 15, 30, and 45 cm yielded R2 values of 0.975-0.988 and RMSE values of 1.08-1.66% v/v. Freshwater groundwater calibration over the measured 0-200 cm range yielded R2 = 0.99946 and RMSE = 1.35 cm. The salinity experiment comprised 990 raw observations from 12 sensor probes and 12 solution batches. Outcome-independent robust QC flagged 60 observations (6.06%), leaving 930 observations for analysis. The pooled quadratic calibration achieved R2 = 0.99771 and RMSE = 3.02 cm, while EC-specific models yielded R2 values of 0.99852-0.99892 and RMSE values of 2.08-2.45 cm. Repeated-measures analysis showed significant main effects of depth and EC but no statistically significant Depth × EC interaction. The maximum mean relative ADC deviation from the EC = 0.5 dS m-1 reference was 1.82% at EC = 4.0 dS m-1 and 200 cm. Field validation quantified linear association, bias, and agreement with reference instruments. Communication exceeded 90% packet delivery at 8 km in open terrain and 5 km in dense sugarcane under the tested conditions. Routine scheduled sensing required 16.60 mWh day-1 with BLE disabled.

