Stroke After Transcatheter Aortic Valve Replacement With Contemporary Valves: Insights From the OCEAN-TAVI Registry
Yusuke Watanabe1, Masanori Yamamoto2,3,4, Hirofumi Hioki5
1Department of Cardiology, Teikyo University School of Medicine, Tokyo, Japan.
Background:
Stroke remains a serious complication after transcatheter aortic valve replacement (TAVR), even with contemporary devices. The objective of the study was to evaluate the incidence, predictors, and prognosis of in-hospital stroke in patients undergoing TAVR with contemporary valve platforms.
Methods:
We analyzed 5123 patients from the multicenter OCEAN-TAVI registry who underwent TAVR with SAPIEN 3 Ultra RESILIA, Evolut FX, or Navitor between May 2022 and December 2024. Stroke incidence across valve types was compared using inverse probability of treatment weighting (IPTW). Predictors were assessed using multivariable Firth penalized logistic regression.
Results:
In-hospital stroke occurred in 2.5% of patients. After IPTW adjustment, stroke incidence differed among valve types: 1.7% of patients treated with SAPIEN 3 Ultra RESILIA (S3UR), 4.5% with Evolut FX, and 2.4% with Navitor (p = 0.044). Disabling stroke was more frequent with Evolut FX (2.5%) compared with S3UR (0.4%) and Navitor (0.7%; p < 0.001). Self-expanding valve use (adjusted odds ratio [aOR] 2.64, 95% CI 1.67-4.16 for Evolut FX; aOR 2.37, 95% CI 1.35-4.18 for Navitor; both vs. S3UR), prior stroke (aOR 1.83, 95% CI 1.19-2.73), reduced renal function, and nontransfemoral access (aOR 2.11, 95% CI 1.29-3.45) were independently associated with in-hospital stroke. One-year survival was significantly lower among patients with stroke than among those without stroke (73.0% vs. 90.3%; p < 0.001).
Conclusions:
In-hospital stroke remains an important complication after contemporary TAVR and is associated with worse clinical outcomes. Differences in stroke incidence across valve types were observed, highlighting the need for improved risk assessment.
Related Concept Videos
Aortic Regurgitation III: Medical Management
Aortic Regurgitation I: Introduction
Mitral Stenosis I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Acute Coronary Syndrome III: Diagnostic Studies
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...