Methylene-tuned sulfonic acid-functionalized silica stationary phases for multi-mode chromatography
Related Experiment Video
Updated: Oct 30, 2026

Imine Metathesis by Silica-Supported Catalysts Using the Methodology of Surface Organometallic Chemistry
Published on: October 18, 2019
Yali Yang1, Ying Zhang2, Kaijun Quan3
1CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou, 730000, China; Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China.
Abstract:
Traditional single-mode stationary phases often suffer from limited separation capability for complex samples containing both hydrophobic, hydrophilic, and ionizable components, requiring multiple column switches that reduce efficiency and increase method complexity. Mixed-mode stationary phases providing two or more retention mechanisms on a single column offer a promising solution. In this study, two novel stationary phases, phenylmethanesulfonic acid-modified silica (Sil-SMSa) and benzenesulfonic acid-modified silica (Sil-SSa), were designed and prepared via thiol-ene click chemistry, offering reversed-phase chromatography (RPLC), hydrophilic interaction liquid chromatography (HILIC), and ion exchange chromatography (IEC) modes, enabling effective separation of nucleobases and nucleosides, vitamins, flavonoids, sulfonamides, polycyclic aromatic hydrocarbons (PAHs), and rare earth elements (REEs). Compared with in-house C18 column and HILIC columns, both Sil-SMSa and Sil-SSa showed better selectivity, broader polarity coverage, and lower solvent consumption. The methylene spacer for Sil-SMSa improved sulfonic acid group (-SO3-) arrangement and hydrophilic layer order, enhancing the resolution of structurally similar compounds. In contrast, the sulfonic acid groups of Sil-SSa are directly attached to the benzene ring, the surface is more rigid and the hydrophilic layer is restricted, leading to stronger electrostatic interactions in HILIC and IEC. This comparison provides evidence for how surface structure regulates multi-mode separation performance and guides the rational design of advanced materials. This work demonstrates that subtle structural variations, such as the presence or absence of a methylene spacer, can significantly modulate separation selectivity and retention behavior, highlighting the importance of the spacer in the development of high-performance multi-mode stationary phases.
More Related Videos
10:14Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
10:41Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Analyte Adsorption and Distribution
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...