Portable X-ray imaging of simulated radiological dispersal devices
Related Experiment Video
Updated: Oct 31, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Erik Rajchl1, Daniel Sas1, Zbyněk Pokorný2
1NBC Defence Institute, University of Defence, Vyškov, Czech Republic.
Abstract:
Radiological dispersal devices (RDDs), often described as dirty bombs, represent a specific operational problem for explosive ordnance disposal (EOD) units because they combine the tactical requirements of an improvised explosive device response with radiation protection constraints. This article evaluates portable radiation detection and X-ray imaging systems under field conditions simulating radiological dispersal devices. Sealed sources of 137Cs and 60Co with activities ranging from 6.3 MBq to 4.74 GBq, together with a liquid 241Am source and an Am-Be neutron source, were placed in simulated IED configurations enclosed in metal, wood, cardboard and plastic. Dose-rate measurements were performed at 20 cm and 100 cm using an identiFINDER® R400 and a MultiRAE Pro multi-threat monitor. Radiographic diagnostics were performed using a NOVO digital X-ray system and a DÜRR computed radiography system. The results show that increasing source activity and gamma-ray energy substantially affect radiation detector performance and radiographic image quality. In contrast, the low-energy alpha emitter 241Am and the Am-Be neutron source had negligible effects on radiographic image quality despite presenting distinct detection challenges for field responders. The NOVO system maintained diagnostically useful images even in the presence of multi-giga-becquerel gamma sources, whereas the DÜRR system showed progressive radiation-induced image degradation, particularly for high-activity 60Co. The findings indicate that radioactive material does not automatically prevent successful radiographic diagnostics of a suspected RDD, but the choice of imaging technology and detector has direct operational consequences for EOD response. The findings provide practical guidance for equipment selection and integrated EOD-CBRN response to suspected RDD incidents.
More Related Videos
Related Concept Videos
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...

