Ultrasound Evaluation of the Abductor Hallucis Muscle in Youth: A Reliability Study
Related Experiment Video
Updated: Oct 31, 2026

Evaluating the Function of the Foot Core System in the Elderly
Published on: March 11, 2022
Maisie Squibb1, Dean Monks1, Christopher D Nulty1
1Department of Health & Sports Science, The EVOLVE Research Group, South East Technological University (SETU), Carlow, Ireland.
Introduction:
Abductor hallucis (AbdH) is an intrinsic foot muscle and a stabiliser of the medial longitudinal arch. Its cross-sectional area (CSA) is routinely measured by ultrasound (US) and is highly relevant to foot muscle development. However, the reliability of portable US for measuring AbdH CSA in healthy youth is unknown. Therefore, the aim of this study was to examine the inter-device association, inter-rater reliability and inter-session reliability of portable US for measuring AbdH CSA in youth.
Methods:
Twenty-seven youths (11-17 years; 14 male, 13 female) participated, with inter-device association and inter-rater reliability assessed in a subgroup of n = 12 and intra-rater inter-session reliability in n = 15. AbdH CSA images were captured on two occasions one week apart using a 5-15 MHz handheld US unit (L15HD, Clarius), while a single image was captured using a cart-based US device (3-16 MHz; HS40, Samsung) for inter-device comparison. Reliability was assessed using intraclass correlation coefficients (two-way mixed-effects, absolute agreement). Inter-device comparison was evaluated using Pearson's correlation, linear regression and paired-sample t-test for systematic differences, and measurement error was quantified using the standard error of measurement (SEM).
Results:
Portable and cart-based US measurements of AbdH CSA showed a strong positive correlation (r = 0.938, p < 0.001), although mean values were 0.19 cm2 higher with the cart-based device (p = 0.002). Inter-rater reliability was excellent (ICC(3, 3) = 0.934, 95% CI: 0.786-0.980) with no significant difference between assessors (p = 0.823), minimal bias (-0.01 cm2), and a SEM of 0.039 cm2. Inter-session reliability was also excellent (ICC(3, 3) = 0.969, 95% CI: 0.911-0.989) with no significant difference between sessions (p = 0.788), minimal bias (0.007 cm2) and a SEM of 0.013 cm2.
Conclusion:
A portable US device demonstrated excellent inter-rater and inter-session reliability for measuring AbdH CSA in youth and was strongly associated with cart-based US measurements.

