A latent ODE approach to full-cycle biventricular cardiac motion modeling from cine MRI
Related Experiment Video
Updated: Nov 2, 2026

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
D Brüggemann1, E Krymova1, F Ozdemir1
1Swiss Data Science Center, EPFL and ETH Zürich, Switzerland.
Abstract:
Cardiac magnetic resonance imaging (CMR) captures rich spatiotemporal information about ventricular structure and motion, but conventional risk models use only a few image-derived indices from selected cardiac phases. We present a latent dynamical model that encodes bi-ventricular anatomy and full-cycle cine motion as a continuous latent trajectory, using heart-rate-aware neural ordinary differential equation (ODE) dynamics and a graph-based mesh autoencoder to reconstruct anatomically consistent 3D+t ventricular motion. A covariate-conditioned prior defines the expected end-diastolic latent state, and a Cox proportional hazards model tests whether deviations from this prior predict incident heart failure. We studied 72,386 UK Biobank participants without baseline cardiovascular disease, including 367 incident heart failure events. In a held-out evaluation subset, adding the latent score to refitted pooled cohort equations improved the stratified C-index from 0.704 to 0.785, compared with 0.764 for seven established cardiac markers. Compared with non-graph and non-ODE approaches, the proposed model gave the best trade-off between reconstruction fidelity, generative realism, and downstream prognostic performance. These results suggest that continuous full-cycle modeling of ventricular motion provides informative cardiac phenotypes beyond conventional CMR summaries, while external validation in more representative patient cohorts is required before clinical risk-prediction use.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the drone...
Magnetic Resonance Imaging
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it instrumental in...
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the time...
Imaging Studies IV: Magnetic Resonance Imaging
