Translating CGM Regulatory Performance Metrics Into Clinical Interpretation: An Exploratory Expert Consensus Framework
Related Experiment Video
Updated: Nov 4, 2026

Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
Alex Ramírez-Rincón1, Ana M Gómez2, Carlos A Yepes-Cortés2
1Clínica Las Américas, AUNA and Universidad Pontificia Bolivariana, Medellín, Colombia.
Background:
Continuous glucose monitoring (CGM) performance is characterized by technical metrics that are inconsistently standardized across regulatory frameworks and variably connected to clinically meaningful outcomes, complicating interpretation and cross-device comparison.
Objectives:
To develop an exploratory framework translating CGM performance characteristics and derived metrics into clinically interpretable domains while distinguishing empirical evidence from expert judgment.
Methods:
Candidate metrics were extracted from contemporary clinical, technical, and regulatory sources and organized into six functional domains. Targeted PubMed searches in ambulatory adults with diabetes evaluated domain-specific technical-to-clinical questions. Evidence was classified as direct device-performance, direct between-device comparative, or indirect/contextual. Five experts participated in two private voting rounds using a virtual Nominal Group Technique and prespecified RAND/UCLA agreement criteria. The study was conducted from November 2025 to January 2026.
Results:
More than 30 metrics and attributes were mapped across analytical accuracy and performance, glycemic exposure, glycemic variability, clinical safety, adherence and device use, and device reliability. Direct evidence was most clearly identified for device-level analytical performance and between-device differences in analytical accuracy and glycemic exposure; evidence in other domains was predominantly indirect, contextual, or device-specific. Twenty-four of 25 statements achieved consensus after round 1 and all 25 after round 2. The panel considered dynamic accuracy, alert functionality when available, and monitoring continuity potentially clinically meaningful, but these ratings did not establish category-wide superiority of FDA-designated integrated CGM systems.
Conclusion:
The framework provides an exploratory structure for interpreting CGM technical performance and derived metrics. Regulatory designation and individual device characteristics should be considered separately, and purpose-designed comparative studies are required to determine whether specific attributes produce reproducible clinical benefits.
Related Concept Videos
Clinically Relevant Drug Product Specifications: Methods of Establishment
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast, controlled...
Drug Product Performance: In Vitro–In Vivo Correlation
Good Manufacturing Practices
Impact of Pharmacokinetic–Pharmacodynamic Models: Regulatory Decisions
Clinical Trials
There are four phases in a clinical trial. A phase one...